User's Manual Part 2
Five: Programming the Valve/Pump Switch Mechanism 37
Providing a brighter solution.™
Installing the Three-Button Wired Remote Control
The Three-Button Wired Remote Control (133PE1484A) can be installed to 
plug into either the Three-Circuit Clock (PE1353ME) or Valve/Pump Switch 
(PE4243ME). 
When plugged into one of these mechanisms, it replaces the wireless method 
of controlling the three circuits within the mechanism. For example, if you plug 
the Three-Button Wired Remote Control into the Valve/Pump Switch, the two 
relays and the pool/spa control will no longer be controllable using the Hand-
Held Wireless Remote. The Three-Button Wired Remote Control must be installed where a third 
mechanism is needed in the enclosure box, since the Wireless Hand-Held Remote. can only 
control two mechanisms.
See illustrations below for connection detail.
Installing Other Wired Remote Connections (Master Switch)
You can install any ON/OFF switch to the sensor line to provide wired control of the two relays 
and the Pool/Spa actuators in the Valve/Pump Switch (PE4243ME), giving you dual control 
(master switch and wireless) control of these circuits.
In use, a wired remote switch toggles all circuits to their opposite state. This means that if 
Relays 1 and 2 are ON, and the actuator valve is in SPA, the wired remote switch will turn 
Relays 1 and 2 OFF, while switching the actuator valve to POOL. It does this by toggling 
Relays 1 and 2 and the actuator valve back and forth from their default state in order to return 
the system to its default setting after the owner has made temporary changes to the settings. 
For example, if using the phone while sitting in the spa, the owner may turn off the jets to 
reduce noise. The next time the Master Switch is used, the jets will revert to being ON when 
the system is in spa mode.
INSTALLATION ISSUE: If you want to change the default state for your installation and you 
manually press the switches on the Valve/Pump Switch control panel, your changes will be 
temporary with the wired remote switch (master switch) because it will return the circuits to their 
factory default setting when it is activated, eliminating your custom settings.
Therefore, if you want to make permanent changes to the factory 
defaults, you must use the jumper, as shown at the right. Then the 
wired remote switch’s return to defaults will not delete your changes. 
Putting the jumper on pins 1 and 2 sets the system default state 
to OPEN = OFF. This is the factory default state.
Putting the jumper on pins 2 and 3 sets the system default state 
to CLOSED = ON.
•
•
Three-Button Wired 
Remoe Control 
(133PE1484A)
Three-Button Wired 
Remoe Control 
(133PE1484A)
Connection to 
Valve/Pump Switch 
(PE4243ME)
Connection to 
Valve/Pump Switch 
(PE4243ME)
Connection to 
Three-Circuit Clock 
(PE1353ME)
Connection to 
Three-Circuit Clock 
(PE1353ME)