User's Manual Part 1
24 I-Wave Installation Guide
Copyright © 2006 Intermatic, Inc.
Connection for Sta-Rite Heaters
Turn off power to heater at main circuit breaker panel.
Unbolt and remove the upper jacket 
halves (Refer to heater owners 
manual).
Open control box cover. (See 
Figure 3-21.)
Remove the factory-installed jumper 
between the Fireman’s Switch 
terminals. (See Figure 3-22. )
Connect two #14 gauge 
wires, designed for use in hot 
environments, to the two black 
wires, marked heater connection, 
on the panel mount receiver in the 
I-Wave Control Center and attach 
the other end to the two spade 
terminals at the heater. You can also 
cut the yellow jumper wire and wire 
connect the black wires to each 
yellow wire. (See Figure 3-23.)
Route the wires out through the 
knockout on the bottom of the 
Control Box. 
Do not disconnect high limit or 
pressure switches.
Turn the heater on and maximize 
the temperature setting.
1.
2.
3.
4.
5.
6.
7.
8.
     Figure 3-21           Figure 3-22     Figure 3-21           Figure 3-22
Figure 3-23Figure 3-23