User's Manual Part 2
28 I-Wave Installation Guide
Copyright © 2006 Intermatic, Inc.
Mode 2 — (Pump High, Pump Low, Aux3)
Circuit one and two are dedicated single pole
outputs for a two-speed pump load. Circuits one and
two will never be ON at the same time, consistent
with a two-speed pump application. Circuit
three is single pole circuit for a generic load, and
independent of circuits one and two..
Mode 3 — (Pump, Aux2, Cleaner Pump)
Circuit one and three are dedicated single pole
outputs for a single speed pump working with a
pressure side cleaner pump. Circuit three will never
come on unless circuit one is on for at least one
minute, consistent with a pressure side cleaner
pump. Circuit two is a single pole circuit for a
generic load, independent of circuits one and three..
Figure 4-4Figure 4-4
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
Figure 4-5Figure 4-5
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.
NOTE: This drawing illustrates
that only one leg is broken, with
the other leg going directly to
load, whether 120V or 240V.