User's Manual Part 2
Seven: Checking Out System / Troubleshooting 47
Providing a brighter solution.™
Section 7:
Checking Out the System /
Troubleshooting
After you have completed installation and programming, make sure the system is working OK
by completing the checklist below. Later on, if problems develop in using the system, this same
checklist will help you troubleshoot the problem.
When you nish checking each item, place a check mark in the box at the right.
What to check How to run the check
TROUBLESHOOTING —
What to do if it doesn’t work
✔
Time of Day Setting Verify that display on Three-Circuit Clock
Mechanism (P1353ME) is showing correct
time of day.
Follow instructions for setting the
correct time on page 30 of this
manual.
Recheck that the set time is correct.
1.
2.
Check circuits on the Three-
Circuit Clock Mechanism
(P1353ME)
Press the rst ON/OFF button on the face of
the mechanism.
Verify that the Hand-Held Receiver shows
that the circuit has powered on.
Verify that the wired function activates
properly (e.g., a pump comes on).
Turn the circuit off using the appropriate
button on the Hand-Held Remote.
Repeat with ON/OFF buttons two and three.
1.
2.
3.
4.
5.
If any of the circuits don’t work:
Check your wiring for the circuit.
Make sure you have set the correct
Mode for the installation. See page
27 of this manual.
If the Hand-Held Remote fails
to turn off the circuit, check its
programming. See page 39 of this
manual.
1.
2.
3.
Check circuits on the Valve/
Pump Switch Mechanism
(P4243ME)
Press the RELAY 1 button on the face of the
mechanism.
Verify that the Hand-Held Receiver shows
that the circuit has powered on.
Verify that the wired function activates (e.g.,
a pump comes on).
Turn the circuit off using the appropriate
button on the Hand-Held Remote.
Repeat with the RELAY 2 button.
1.
2.
3.
4.
5.
If any of the circuits don’t work:
Check your wiring for the circuit.
Make sure you have set the correct
Mode for the installation. See page
27 of this manual.
If the Hand-Held Remote fails
to turn off the circuit, check its
programming. See page 39 of this
manual.
1.
2.
3.
Check that the Actuator
valves correct switch
between pool and spa.
Press the VALVES button on the Valve/Pump
Switch Mechanism (P4243ME).
Verify that the Hand-Held Receiver shows
that the actuator valves have changed
position.
Verify that the actuator valves have correctly
switched position.
Switch the valves back using the P/S button
on the Hand-Held Remote.
1.
2.
3.
4.
If any of the valves don’t switch:
Check your wiring for the circuit.
If the Hand-Held Remote fails
to turn off the circuit, check its
programming. See page 39 of this
manual.
1.
2.
Check that the actuator
valves are synchronized.
As you watch them move back and forth, verify
that the valves are oriented the same way: to
pool, then to spa
Re-synchronize the valves. See page 21
of this manual.
Verify that the Hand-Held
Remote is controlling pool
and spa temperature.