User's Manual Part 2
44 I-Wave Installation Guide
Copyright © 2006 Intermatic, Inc.
Operating Programmed Functions
Depending on how you have wired the system, the ve function buttons on the Hand-Held
Remote control the ve circuits in the Control Center. You should apply the appropriate label to
the ve buttons — describing the appropriate equipment according to your installation — from
the assortment of labels supplied.
Buttons <1>, <2>, and <3> control circuits 1, 2, and 3 on the Three-Circuit Clock
Mechanism (P1353ME) that is installed on the left side of the Control Center.
Buttons <4> and <5> control Relay 1 and Relay 2 on the Valve/Pump Switch Control
(P4243ME) that is installed on the right side of the Control Center.
When you press any of these buttons, the appropriate circuit toggles ON or OFF. In addition,
when the circuit is ON, the Hand-Held Controller’s display shows the circuit number along the
top of the screen.
Advanced Features
Configuring Two or More Hand-Held Remote Controllers
Many installations will nd it convenient to use two Hand-Held Remote Controllers. Once you
have linked one Hand-Held to the Control Center, it’s easy to add a second controller to the
network.
Make sure the Hand-Held you are adding to the network has been reset, with any previous
programming deleted.
Press any button on the Hand-Held Remote to wake it from sleep.
(The unit goes to sleep to conserve battery life when it has been
idle for 30 seconds.)
Press and hold the <P/S> and <CHLR> buttons at the same time
for about 5 seconds. This will put the device in programming
mode, as shown at the right.
Press the <4> function button to select RESET CONTROLLER. The
device resets and the word SUCCESS appears at the bottom of the
screen.
On both Hand-Held units, press and hold the <P/S> and <CHLR>
buttons at the same time for about 5 seconds to put them into
programming mode, as shown at the right.
•
•
1.
a.
b.
c.
2.
STAT
OK
POOL
72
ºF SET
P 72
S 85
STAT
OK
POOL
72
ºF SET
P 72
S 85
LEARN VER x
1 INCLUDE NODE
2 ADD TO GROUP
3 RESET NODE
4 RESET CONTROLLER
5 MORE OPTIONS
C EXIT
LEARN VER x
1 INCLUDE NODE
2 ADD TO GROUP
3 RESET NODE
4 RESET CONTROLLER
5 MORE OPTIONS
C EXIT
LEARN VER x
1 INCLUDE NODE
2 ADD TO GROUP
3 RESET NODE
4 RESET CONTROLLER
5 MORE OPTIONS
C EXIT
SUCCESS
LEARN VER x
1 INCLUDE NODE
2 ADD TO GROUP
3 RESET NODE
4 RESET CONTROLLER
5 MORE OPTIONS
C EXIT
SUCCESS
LEARN VER x
1 INCLUDE NODE
2 ADD TO GROUP
3 RESET NODE
4 RESET CONTROLLER
5 MORE OPTIONS
C EXIT
LEARN VER x
1 INCLUDE NODE
2 ADD TO GROUP
3 RESET NODE
4 RESET CONTROLLER
5 MORE OPTIONS
C EXIT