User's Manual Part 2

Five: Programming the Valve/Pump Switch Mechanism 37
Providing a brighter solution.™
Installing the Three-Button Wired Remote Control
The Three-Button Wired Remote Control (133PE1484A) can be installed to
plug into either the Three-Circuit Clock (PE1353ME) or Valve/Pump Switch
(PE4243ME).
When plugged into one of these mechanisms, it replaces the wireless method
of controlling the three circuits within the mechanism. For example, if you plug
the Three-Button Wired Remote Control into the Valve/Pump Switch, the two
relays and the pool/spa control will no longer be controllable using the Hand-
Held Wireless Remote. The Three-Button Wired Remote Control must be installed where a third
mechanism is needed in the enclosure box, since the Wireless Hand-Held Remote. can only
control two mechanisms.
See illustrations below for connection detail.
Installing Other Wired Remote Connections (Master Switch)
You can install any ON/OFF switch to the sensor line to provide wired control of the two relays
and the Pool/Spa actuators in the Valve/Pump Switch (PE4243ME), giving you dual control
(master switch and wireless) control of these circuits.
In use, a wired remote switch toggles all circuits to their opposite state. This means that if
Relays 1 and 2 are ON, and the actuator valve is in SPA, the wired remote switch will turn
Relays 1 and 2 OFF, while switching the actuator valve to POOL. It does this by toggling
Relays 1 and 2 and the actuator valve back and forth from their default state in order to return
the system to its default setting after the owner has made temporary changes to the settings.
For example, if using the phone while sitting in the spa, the owner may turn off the jets to
reduce noise. The next time the Master Switch is used, the jets will revert to being ON when
the system is in spa mode.
INSTALLATION ISSUE: If you want to change the default state for your installation and you
manually press the switches on the Valve/Pump Switch control panel, your changes will be
temporary with the wired remote switch (master switch) because it will return the circuits to their
factory default setting when it is activated, eliminating your custom settings.
Therefore, if you want to make permanent changes to the factory
defaults, you must use the jumper, as shown at the right. Then the
wired remote switch’s return to defaults will not delete your changes.
Putting the jumper on pins 1 and 2 sets the system default state
to OPEN = OFF. This is the factory default state.
Putting the jumper on pins 2 and 3 sets the system default state
to CLOSED = ON.
Three-Button Wired
Remoe Control
(133PE1484A)
Three-Button Wired
Remoe Control
(133PE1484A)
Connection to
Valve/Pump Switch
(PE4243ME)
Connection to
Valve/Pump Switch
(PE4243ME)
Connection to
Three-Circuit Clock
(PE1353ME)
Connection to
Three-Circuit Clock
(PE1353ME)