User's Manual Part 1
One: System Overview 9
Providing a brighter solution.™
Wireless Hand-Held Transceiver (PE950)
The main function of the Wireless-Hand-Held Transceiver is to transmit user
commands to the Panel Mount Transceiver. The device can control up to ve
loads, typically:
The three loads in the Three-Circuit Clock
The two relays in the Valve/Pump Switch, usually water temperature
controls for pool/spa
The actuators that switch between pool and spa
The unit oats if thrown in the pool or spa, is water-submersible, shock
resistant, and requires three (3) AA batteries (supplied). Expected battery life
is about one year in typical use.
The Wireless Hand-Held Transceiver can only communicate with the Panel-Mounted Transceiver
and Transceiver Repeater Module, and is compatible with no other hardware. In addition, when
the components of a specic system are linked together into a network, communication with
another neighboring system cannot occur.
Transceiver Repeater Module
The Transceiver Repeater Modules (HA04C) ensure that no problems in
reception occur between the Hand-Held Controller(s) and the Panel-Mounted
Transceiver. Reception is affected by distance (about 100 feet, direct line of sight)
and by physical obstacles (like brick walls or structures). However, by plugging
in a Transceiver Repeater Module where necessary, long distances or physical
obstructions can be overcome.
The I-Wave System includes one Transceiver Repeater Module. Additional units can be odered
from Intermatic.
OMRON Relay Assembly (143T145A)
There are two OMRON Relay Assemblies (143T145A) in the Valve/Pump
Switch Mechanism ( ) which switch either 120V or 240V loads. These
relays are replaceable and can be ordered separately.
Water Temperature Sensor (178PE4)
The Intermatic Water Sensor (178PE4) monitors both pool and spa water
temperature, depending on the position of the diverter valves. Installation
is necessary for the thermostatic control to work. The sensor can be
ordered separately.
•
•
•
CONTACT RATINGS – EACH CIRCUIT
17A Resistive, 120/240 VAC., 50/60 Hz
1.5 HP @ 120 VAC., 50/60 Hz
3.0 HP @ 240 VAC., 50/60 Hz
10 Amp Tungsten, 120/240 VAC, 50/60 Hz
•
•
•
•
CONTACT RATINGS – EACH CIRCUIT
17A Resistive, 120/240 VAC., 50/60 Hz
1.5 HP @ 120 VAC., 50/60 Hz
3.0 HP @ 240 VAC., 50/60 Hz
10 Amp Tungsten, 120/240 VAC, 50/60 Hz
•
•
•
•