24 I-Wave Installation Guide
Copyright © 2006 Intermatic, Inc.
Connection for Sta-Rite Heaters
Turn off power to heater at main circuit breaker panel.
Unbolt and remove the upper jacket
halves (Refer to heater owners
manual).
Open control box cover. (See
Figure 3-21.)
Remove the factory-installed jumper
between the Fireman’s Switch
terminals. (See Figure 3-22. )
Connect two #14 gauge
wires, designed for use in hot
environments, to the two black
wires, marked heater connection,
on the panel mount receiver in the
I-Wave Control Center and attach
the other end to the two spade
terminals at the heater. You can also
cut the yellow jumper wire and wire
connect the black wires to each
yellow wire. (See Figure 3-23.)
Route the wires out through the
knockout on the bottom of the
Control Box.
Do not disconnect high limit or
pressure switches.
Turn the heater on and maximize
the temperature setting.