User's Manual Part 1

Three: Control Center Installation 21
Providing a brighter solution.™
Motorized Valve Actuator Connection and Synchronizing
The I-Wave Control System is capable of controlling up to three Motorized Valve Actuators. Two
Intermatic Motorized Valve Actuators (PE24VA) are included with your I-Wave system. Contact
Intermatic Customer Service to order additional actuators.
The actuators must be installed to automatically rotate your valves between pool and spa
plumbing. Power must be disconnected when connecting the actuator connectors to your I-Wave
Control Center. Refer to the directions below prior to installing your PE24VA actuators. Refer to
Figure 3-13 for detail.
Remove power from the I-Wave control center.
Attach the valve actuators (PE24VA) to the water valves. (See instructions included.)
Run the actuator cable to the Control Center, and through the low voltage raceway.
Remove the access door to the Pump/Valve Switch mechanism.
Insert the three-pin connector of the motorized valve actuator to any of the three available
connectors on the Pump/Valve Switch mechanism circuit board.
Apply power to the I-Wave Control Center and synchronize the actuators as follows:
Use the Valve button located on your Pump/Valve switch to illuminate the green light
above the Valve switch. This indicates that the switch is in SPA mode.
Use the switch located on your motorized valve actuator to ensure the valves are in the
SPA position.
If either of the Actuators is positioned backwards, ip the switch on the back to reverse
position.
Verify that the Actuators are correctly synchronized with your installation.
1.
2.
3.
4.
5.
6.
a.
b.
c.
d.
Figure 3-13Figure 3-13