User's Manual Part 1

Three: Control Center Installation 19
Providing a brighter solution.™
Low-Voltage Underwater Lights
CAUTION: Your I-Wave Control Center is equipped with a Low Voltage Raceway.
You must use this raceway for all low voltage wiring, including the 12 Volt wires
from the transformer. You cannot mix high and low voltages in the high voltage
compartment.
NOTE: If you require a low voltage transformer, you should order system model PE45343RCT1
(with a 100 watt transformer) or PE45343RCT3 (with a 300-watt transformer). Alternatively, you
can order a 300-watt PA116 or 100-watt PA117 12V transformer kit to mount in the standard
system model PE45343RC. (See Figure 3-9.)
If required by local code, install a GFCI receptacle and connect the neutral and hot wire, from
the circuit breaker, to the LINE side of the GFCI. (See Figure 3-10.)
Connect the lite to the secondary side of the transformer.
Connect the neutral side of the transformer to the load side of the GFCI.
Connect the hot as follows:
To the LOAD side of clock,
Then out the LINE side of the clock to the LOAD side of the GFCI. (See Figure 3-10.)
Connect the ground (green wire) from the light to the grounding bar inside the Control Center.
1.
2.
3.
4.
a.
b.
5.
Figure 3-9 Figure 3-10 Figure 3-9 Figure 3-10