21-3609E rev1.0 xL Regional Settings Guide 81
40 Doors Locked Out.
41 Doors Held Open.
42 Doors Forced.
43 Door Tampers (door contact condition:
no EOL resistor etc.)
44 Doors Open.
45 Doors Secure.
46 Door Sensor Troubles (magnetic bond
sensor not ok)
47 Panic Token Detected.
48 Area “Empty” (User count <= minimum).
49 Area ”Full” (User Count >=Maximum).
50 No Detected Activity in Area.
51 Activity Detected in Area.
52 15 minutes prior to Scheduled “Arm to
ON” Level.
53 15 minutes prior to Scheduled “Arm to
STAY” Level.
54 15 minutes prior to Scheduled “Arm to
OFF” Level.
55 Area schedule is active.
56 Auto-command schedule is active.
57 Failed to close.
58 Any point in tamper in area.
59 Area armed with points bypassed.
60 Area Force Armed.
61 Invalid Card / PIN Lockout present.
62 Wandering Patient detected.
European Version (Area)
63 Siren
64 Confirmed Alarm Strobe
65 Fire
66 Personal Attack
67 Unconfirmed Alarm
68 Set / Unset
69 Freezer / Fire Fault
70 Bypass in Effect
71 Confirmed Alarm
Program Section (“q”)
“P”oint (
Inputs)
Section Range
(“nnn”)
Enter 001 – 128
Code “cc”
Description
00 When point is NORMAL.
01 Any time the point is NOT NORMAL
(open, tamper, alarm)
02 When point is NOT NORMAL in OFF or
STAY (open, tamper, alarm)
03 When point is NOT NORMAL in ON
(open, tamper, alarm)
04 When point is in ALARM
05 When point is BYPASSED
06 When the time delay is active (Pre-alarm
Warning).
07 Point is in Tamper.
08 Point is in Delay. Follows a Custom Pt
Type that has a time delay.
09 Positive confirmation of Command Point
activation.
Program Section (“q”)
“B” Output State
Section Range
(“nnn”)
Enter 001 – 128
Code “cc”
Description
00 An actual output is on.
01 Equation Output is TRUE
02 Manual Command is in effect from the
Director software Outputs Section,
Control & Status.
WARNING: Access Control related outputs can only be used with
the addition of the “Feature Expansion Board
”.
Program Section (“q”)
“R” Doors
Section Range
(“nnn”)
Enter 001 – 032
Code “cc”
Description
00 Door Unlocked
01 Door Locked Out
02 Door Held Open
03 Door Forced
04 Door Tamper (door contact condition: no
EOL resistor etc.)
05 Door Open
06 Door Secure
07 Door Sensor Trouble (magnetic bond
sensor not ok)
08 Door Blocked by Interlock Condition
09 Wandering Patient Detected
10 Door entry Delay in Effect
Program Section (“q”)
“F” loors
Section Range
(“nnn”)
Enter 001 – 124
Code “cc”
Description
00 Floor Desecure
Program Section (“q”)
“M” odule
Section Range
(“nnn”)
Enter 01 – 24
Code “cc”
Description
00 On Line
01 Tamper
02 Comms Trouble (Substitution & Comms)
03 Battery Trouble (Module)
04 User logged on to e.g. LCD keypads
Program Section (“q”)
“C” Suite
Section Range
(“nnn”)
Enter 01 – 24
Code “cc”
Description
00 Alarm
01 Fire
02 Tamper
03 Siren / Sonalert
04 Module Communications Trouble
05 Suite Normal (No Alarm, Fire, Tamper,
Siren / Sonalert, Comms Trouble)
06 Suite in STAY level.
07 Suite in ON level.
08 Suite in STAY or ON level.