User Manual
21-3609E rev1.0 xL Regional Settings Guide 79
B008:01
“T 100 Timer ”
B009:00 (WW STU)
B009:01
“? S000.65 Query ”
“T 100 Timer ”
ACPO Confirmed Alarm
B010:00 (WW STU)
B010:01
“? A001.32 Query ”
“T 000 Timer ”
Area is in ‘Walk’ or ‘Hold-up’ test.
Output Timer Delays and Special Codes
(Bxxx:01)
00: undefined;
01: 1 sec;
02: 2 sec;
03: 3 sec;
04: 5 sec;
05: 10 sec;
06: 15 sec;
07: 20 sec;
08: 30 sec;
09: 45 sec;
(09: China/
HK=40 sec)
10: 60 sec;
11: 90 sec;
(11: China/
HK=100 sec)
12: 2 min;
13: 3 min;
14: 5 min;
15: 10 min;
16: 15 min;
17: 20 min;
18: 30 min;
19: 45 min;
20: 60 min;
21: 90 min;
22: 2 hr;
23: 4 hr;
24: 6 hr;
25: 8 hr;
26: 10 hr;
27: 12 hr;
28: 16 hr;
29: 20 hr;
30: 1 day;
31: 1 week
Special Codes:
98 = toggle
99 = output off
Output Selections Table
WARNING: Access Control related outputs can only be used
with the addition of the “Feature Expansion Board
”.
Program Section (“q”)
“S”ystem
Section Range
(“nnn”)
000 – 000
Code “cc”
Description
00 Fallback sonalert (at control panel) if
Module Bus fails. Provides 1 sec. Output
every 8 sec. And activates if there is no
operational keypad in an area with
programmed keypads.
01 Not Used
02 When system is FULLY ON
03 PARTIALLY ON. One or more areas
ON.
04 When system is FULLY OFF
05 When system is IN ALARM - resets
when point(s) restore
(includes equipment failure & tampers)
06 Follows ALARM (BURG / EMERG) &
FIRE siren steady.
07 Follows ALARM siren - steady for BURG
/ EMERG. Keypad tone & siren is 1 sec
on/off for FIRE.
For UL: When using this output type,
fire siren is ½ sec on/off three times, 1.5
sec pause, and repeats. Keypad tone is
1 sec on/off.
08 Follows ALARM siren - steady for BURG
/ EMERG and provides 2 sec on/off for
FIRE
09 Digital PHONE LINE trouble (follows
report delay or line failure)
10 System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off then back on again)
11 When there is a point BYPASSED
somewhere in the system
12 When any ‘FIRE’ point is in alarm
13 When any ‘HOLD UP’ point is in alarm
14 When any ‘Aux Alert' point is in alarm
15 When any ‘VAULT / SAFE’ type point is
in alarm
16 When any ‘'Burglary' point is in alarm.
Delayed burglary for European
Version.
17 When any ‘Supervisory' point is in alarm.
18 When any 'Equipment Failure' is in alarm
19 Equipment Failure 1 – System Trouble /
All type tamper for European Version.
20 Equipment Failure 2 – Battery Trouble
21 Equipment Failure 3 – AC (Mains)
Trouble
22 Equipment Failure 4 – Phone Trouble
23 Equipment Failure 5 – Report Delay
24 Equipment Failure 6 – Time Lost
25 Equipment Failure 7 – Time Change
26 Equipment Failure 8 – Program Change
27 Equipment Failure 9 – Program Error
28 Equipment Failure 10 – Fuse Failure
29 Equipment Failure 11 – Module Trouble
30 Equipment Failure 12 – Module Battery
Low
31 Equipment Failure 13 – Module Program
Edit
32 Equipment Failure 14 – Module Program
Error
33 Equipment Failure 15 – Misc. Trouble
34 Equipment Failure 16 – SIP Trouble
35 Duress Pin
36 Doors Unlocked.
37 Doors Locked Out
38 Doors Held Open
39 Doors Forced
40 Doors Tamper (door contact condition:
no EOL resistor etc.)
41 Doors Open
42 Doors Secure
43 Doors Sensor Trouble (magnetic bond
sensor not ok)
44 Global Invalid PIN and / orCard lockout.
45 Host (Director) computer is On-Line.
46 Host (Director) computer is Off-Line.
Response time for IP, external modem,
direct connection is 2 min. Bell 103 is 1
min.
47 SIP On-Line.
48 SIP Off-Line. Response time is 3
minutes.
49 Any point in tamper.
50 Any point in Alarm.
51 Any area is Force Arming