User Manual

xL Regional Settings Guide
21-3609E rev1.0
22
Outputs (UK version)
Select Output Select Group
(Program Section)
Select Condition Select Operation
B001 – B128 System Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm, ACPO Fire, ACPO Attack, ACPO
Unconfirmed, ACPO Set, ACPO F/Faul (Fire
Fault), ACPO Bypass, ACPO Confirmed, ACPO
Siren, ACPO Strobe.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Areas
Select Area #
ACPO Fire, ACPO Attack, ACPO Unconfirmed,
ACPO Set, ACPO F/Faul (Fire Fault), ACPO
Bypass, ACPO Confirmed, ACPO Siren, ACPO
Strobe.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Protection Points
Select Point #
Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Outputs
Select Output #
Real OP (output) On, Equation is True, Manual
Command.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Modules
Select Module #
On Line, Tamper, Comms Trbl, (Communications
Trouble), Battery Trouble, User Loged On.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Equipment Points
Select Point #
System Tmpr (Tamper), Low/No Battery, AC Mains
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.
Toggle, Normal, Time
Delay or Inverted
UK Default Outputs
Select Output Select Group
(Program
Section)
Select Area,
Point, etc.
Select Condition Select Operation
B001 Relay 1
motherboard
System 000.66 ACPO Siren Inverted
B002 Relay 2
motherboard
System 000.67 Confirmed Alarm (ACPO strobe) Inverted
B003 WW STU Areas Area 1 001.33 When area Entry / Exit delay is in
progress – provides a steady output
(STAY & ON).
Normal
B004 WW STU System 000.60 Personal ACPO Attack Normal
B005 WW STU System 000.61 ACPO Unconfirmed Alarm Inverted
B006 WW STU System 000.62 ACPO Area Set / Unset Inverted
B007 WW STU System 000.64 ACPO Bypass in Effect Inverted
B008 WW STU System 000.54 Local AC (mains) failure. Inverted
B009 WW STU System 000.65 ACPO Confirmed Alarm Inverted
B010 WW STU Areas Area 1 001.32 Area is in ‘Walk’ or ‘Hold-up’ test. Inverted
B011 – B128 Undefined
WW STU = World Wide modem with outputs