User Manual

xL Regional Settings Guide
21-3609E rev1.0
12
Input Points
Point Types: EE(entry/exit)Door, EE Route, Perimeter, Motion, Fap Motion, Day Warning, Burglary, Fire Class A, Fire
15s (second), Fire 0s (immediate), Hold-up, Aux Alert (auxiliary alert/emergency), Supervisory, Local 24h (hour), Lcl
StayOn (Local Stay-On), Lcl Stay20n, Local On Only, undefined.
FAP: (False Alarm Preventer) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and
immediately resets, a 20 minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.
Circuit Types: NC (normally closed), NC SERIES2K (normally closed with 2.2K End of Line resistor), NO PARALL2K
(normally open with 2.2K End of Line resistor), DUAL 2K2 EO (Form ā€œCā€ Dual 2.2K End of Line resistor)
Circuit Types UK:
NO, 2K-ALM 1K-O, Type2 2K2EO, Type2 8K2EO.
Point
Location
Regional
Setting
Default Point
Type
Default Name Default Circuit Type Assigned to Default
AREA
N America Entry/Exit Door
FRONT DOOR
NO PARALL2K A01: OFFICE
European Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO Custom # 80
(Command Point,
Class:
Supervisory.
See Custom Point
Programming and
ACPO in Advanced
Programming )
LCLCMDATEALL
NO A01: AREA DE(SCRIP)
Aus/NZ Entry/Exit Door
FRONT DOOR
DUAL 2K2 EO A01: OFFICE
China/H.K. Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 001,
main
control
board.
France Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
N America Entry/Exit Route
(set to ON)
LOBBY MOTION
NO PARALL2K A01: OFFICE
European EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Aus/NZ Entry/Exit Route
(set to ON)
LOBBY MOTION
DUAL 2K2 EO A01: OFFICE
China/H.K. EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 002,
main
control
board.
France EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
N America Motion
(set to ON)
OFFICE MOTION
NO PARALL2K A01: OFFICE
European EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Aus/NZ Motion
(set to ON)
OFFICE MOTION
DUAL 2K2 EO A01: OFFICE
China/H.K. EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 003,
main
control
board.
France EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
N America Motion
(set to ON)
INTR MOTION
(interior motion)
NO PARALL2K A01: OFFICE
European Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Aus/NZ Motion
(set to ON)
INTR MOTION
(interior motion)
DUAL 2K2 EO A01: OFFICE
China/H.K. Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 004,
main
control
board.
France Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 005,
N America Motion
(set to ON)
REAR MOTION
NO PARALL2K A01: OFFICE