User Manual
xL Regional Settings Guide
21-3609E rev1.0
12
Input Points
Point Types: EE(entry/exit)Door, EE Route, Perimeter, Motion, Fap Motion, Day Warning, Burglary, Fire Class A, Fire
15s (second), Fire 0s (immediate), Hold-up, Aux Alert (auxiliary alert/emergency), Supervisory, Local 24h (hour), Lcl
StayOn (Local Stay-On), Lcl Stay20n, Local On Only, undefined.
FAP: (False Alarm Preventer) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and
immediately resets, a 20 minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.
Circuit Types: NC (normally closed), NC SERIES2K (normally closed with 2.2K End of Line resistor), NO PARALL2K
(normally open with 2.2K End of Line resistor), DUAL 2K2 EO (Form āCā Dual 2.2K End of Line resistor)
Circuit Types UK:
NO, 2K-ALM 1K-O, Type2 2K2EO, Type2 8K2EO.
Point
Location
Regional
Setting
Default Point
Type
Default Name Default Circuit Type Assigned to Default
AREA
N America Entry/Exit Door
FRONT DOOR
NO PARALL2K A01: OFFICE
European Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO Custom # 80
(Command Point,
Class:
Supervisory.
See Custom Point
Programming and
ACPO in Advanced
Programming )
LCLCMDATEALL
NO A01: AREA DE(SCRIP)
Aus/NZ Entry/Exit Door
FRONT DOOR
DUAL 2K2 EO A01: OFFICE
China/H.K. Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 001,
main
control
board.
France Entry/Exit Door
FRONT DOOR
TYPE2 2K2EO A01: AREA DE(SCRIP)
N America Entry/Exit Route
(set to ON)
LOBBY MOTION
NO PARALL2K A01: OFFICE
European EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Aus/NZ Entry/Exit Route
(set to ON)
LOBBY MOTION
DUAL 2K2 EO A01: OFFICE
China/H.K. EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 002,
main
control
board.
France EE Door
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
N America Motion
(set to ON)
OFFICE MOTION
NO PARALL2K A01: OFFICE
European EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Aus/NZ Motion
(set to ON)
OFFICE MOTION
DUAL 2K2 EO A01: OFFICE
China/H.K. EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 003,
main
control
board.
France EE Route
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
N America Motion
(set to ON)
INTR MOTION
(interior motion)
NO PARALL2K A01: OFFICE
European Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
U.K. ACPO Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Aus/NZ Motion
(set to ON)
INTR MOTION
(interior motion)
DUAL 2K2 EO A01: OFFICE
China/H.K. Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Netherlands Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Switzerland Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 004,
main
control
board.
France Motion
(set to ON)
CCT DESCRIP
TYPE2 2K2EO A01: AREA DE(SCRIP)
Point 005,
N America Motion
(set to ON)
REAR MOTION
NO PARALL2K A01: OFFICE