21-3609E rev1.0 xL Regional Settings Guide 107
Event Message Reference: Sorted by SIA Code
SIA
CID equiv.
Description / Meaning Level
AR
R301
AC Trouble (E003—Restore) Emergency
AT
E301
AC Trouble (E003) Emergency
BA
E130
Burglary Emergency
BR
R130
Burglary—Restore Emergency
BS
NEW E389
Point-Test Fail Emergency
BT
E383
Burglary—Tamper Emergency
CA
NEW R403
Automatic Area On (Sched. Auto-arm on fail to close) Full
CE
NEW E464
Work late (Closing extended) Emergency
CF
NEW R402
Turn Area On (Bypass or Forced) Full
CI
NEW E454
Fail to Turn Area On (Fail to Close) Emergency
CL
NEW R401
Turn Area On (Normal) Full
DG
E422
Second User Authority Granted for Dual Custody Full
EE
E134
Fail to Exit Area Emergency
ER
R143
Module tamper/comms/subst'n (E011--Restore) Emergency
ET
E143
Module Trouble—tamper/comms/subst’n (E011) Emergency
FA
E110
Fire or Fire-Class A Emergency
FR
R110
Fire or Fire-Class A—Restore Emergency
FT
E380
Fire or Fire-Class A—Tamper Emergency
HA
NEW E121
Duress Pin Emergency
NEW JP
E458
Verify User Emergency
JR
E404
Schedule resumed (Stay opened resume) Emergency
JS
E459
Schedule suspended (Stay opened suspended) Emergency
JT
E625
Time Changed (E007) Emergency
NEW LB
NEW E306
Main panel Config Changed (E008), Module Program Changed (E013) Emergency
LR
R351
Phone Trouble (E004—Restore) Emergency
LS
R330
Main panel Program Error (E009—Restore) (All Regional Settings
Except Netherlands)
Emergency
LT
E351
Phone Trouble (E004) Emergency
LU
E330
Main panel Program Error (E009) (All Regional Settings Except
Netherlands)
Emergency
NEW LX
NEW R306
Main panel Config Changed (E008—Restore), Module Program Changed
(E013—Restore)
Emergency
MA
E100
Aux. Alert Emergency
MR
R100
Aux. Alert—Restore Emergency
MT
E380
Aux. Alert—Tamper Emergency
NF
NEW R456
Turn Area to Stay (Bypass or Forced) Full
NL
NEW R441
Turn Area to Stay (Normal) Full
OA
E409
Automatic Area Off (SDC5 type points) Full
OG
E441
Turn Area to Stay from On Full
NEW OK
NEW E450
Emergency Stay/Unauthorized Off (schedules) Emergency
NEW OK
NEW E451
Unauthorized Stay (schedules) Emergency
OP
E400
Turn Area Off Full
PA
E120
Holdup Emergency
PA or E120 with event
code “299”
Global Lockout Alarm caused by invalid card/PIN use in Area.
Emergency
PR
R120
Holdup—Restore Emergency
PR or R120 with event
code “299”
Global Lockout Alarm Restore in Area.
Emergency
PT
E380
Holdup—Tamper Emergency
QA
NEW E130
Vault/Safe
Emergency
QR
NEW R130
Vault/Safe—Restore Emergency
QT
E380
Vault/Safe—Tamper Emergency
ri
n/a
Area-number reference Emergency
NEW RP
E602
Digital Dialer Comms Test Emergency
RR
NEW E626
Time Lost (E006) Emergency