Spec Sheet

Ordering Information
UM-5000-CPU UltraSync
Modular 500-Zone CPU with IP and PSTN
Specifications
HardwiredZones Upto500total(3.3kEOLresistors)
WirelessSensors Upto192,withoptionalwirelessexpansionmodule(s)
Outputs 5xopencollector
Users 256
Language English
Communication/
Reporting
Ethernet10/100Mbps,RJ-45
PSTNdialer
Cellular(optional)
DataBus
Busextensionuptoanadditional2,600ft(800m)withthe
additionofaSmartPowerSupply
ScrewTerminals Removable,accepts16–30AWG
RFReceiver
Frequency319.5MHz
Sensitivity-120dBm
OperatingVoltage 16–18VAC,18–26VDC
AuxiliaryPower 13.8VDC+/-0.2V,1Amax.
AuxiliaryShutdown 10VDC
CurrentDraw 100mA,CPUonly
StorageTemperature −30°to140°F(−34°to60°C)
Operating Temperature
Non-UL/ULCInstallations 14°to131°F(-10°to55°C)
UL/ULCInstallations 32°to120°F(0°to49°C)
Relative Humidity
Non-UL/ULCInstallations 95%noncondensing
UL/ULCInstallations 85%noncondensing
ApprovalListings
FCC/IC
UL-609 (Local burglar alarm units and systems)
UL-636 (Holdup alarm units and systems)
UL-365 (Police-connected burglar alarm units and systems)
UL-985 (Household fire warning systems)
UL-1023 (Household burglar alarm systems)
UL-1076 (Proprietary burglar alarm units and systems)
UL-1610 (Central station burglar alarm units)
UL-1635 (Digital alarm communicator systems)
UL-1637 (Home healthcare signaling equipment)
CA State Fire Marshal (CSFM)
ULC-S303 (Local burglar alarm units and systems)
ULC-S304 (CMS burglar alarm units)
ULC/ORD-C1023 (Household burglar alarm system units)
ULC-S545 (Residential fire warning system control units)
ULC/ORD-C1076 (Proprietary burglar alarm units and systems)
SIA CP-01 2014
Accessories
For the current list of compatible accessory items, download the latest UltraSync Modular
Hub Product Ordering Guide at interlogix.com/intrusion/category/accessories