User Manual

TVE-120-420-820-1620 Encoder User Manual 61
To restore parameters to default factory settings:
1. From the menu toolbar, click Configuration and then the Remote Configuration >
Device Management > Configuration Files. The Configuration Files window
appears.
Note: Only the administrator can restore the default settings.
2. To restore all parameters to default factory settings:
Click the Default button. Enter the Admin password, click OK, and then click Yes to
confirm that you want to restore all parameters to default.
or
To restore all parameters, except network settings, to default factory settings:
Click the Restore button. Enter the Admin password, click OK, and then click Yes to
confirm that you want to restore all parameters except network settings to default.
The system will automatically restart.
To import/export configuration file
1. Insert an external storage device in the encoder.
2. From the menu toolbar, click Configuration and then Remote Configuration >
Device Management > Configuration Files. The Configuration Files window
appears.
3. To import a configuration file:
Click Browse to select the local configuration file and then click Import to start
importing configuration file from the external storage device.
or
To export a configuration file:
Click Export to export the encoder’s configuration settings into an external storage
device.
Upgrade the system firmware
The firmware on the encoder can be updated using three methods:
Via a USB device
Using TruVision Navigator. For further information, refer to the TruVision Navigator
user manual.
The firmware upgrade file is labeled tve-x20.dav.
To update the system firmware:
1. Download the latest firmware from our web site to your computer or a USD device:
Americas: www.interlogix.com
EMEA: www.firesecurityproducts.com