3. Select Enable Sudden Scene Change.
4. Select the sensitivity of the change.
5. Select the arming schedules for the VCA event.
Click the Arming Schedule tab. Select the day of the week and the time periods
during the day when the sudden scene change can be detected. The configuration
is the same as that for motion detection (see βMotion detectionβ on page 22). You
can schedule only one time period in a day. Default is 24 hours. Click Save to save
the settings. Click Copy to copy these settings to other days of the week.
Click Save to save the settings. Click Copy to copy these settings to other days of
the week.
6. Select the response method to the VCA event.
Click the Actions tab. Under Alarm Linking, check one of more of the desired
response method:
- Enable Alarm Audio: Record audio with the video.
- Notify Alarm Host: Send a notification or alarm signal to remote alarm host
when an event occurs. The alarm host refers to the computer installed with
remote client software
- Send Email: Send an email with alarm information to a user or users when an
event occurs.
Under Trigger Alarm Output select one of more alarm outputs to trigger an
external alarm when a motion detection event occurs. See βAlarm output settingsβ
on page 51 on how to set up an external alarm output.
Under Trigger Channel, select one or more channels to trigger recording when a
motion detection event occurs.
Select the PTZ control actions to link to the VCA event. Under PTZ Linking, select
the PTZ camera and enter the preset, preset tour, and/or a shadow tour to be
triggered when the alarm is detected. Select Enable to activate the option.
7. Click Save to save all the settings.