Select the time threshold, sensitivity levels and percentage of the region.
The time threshold is the time that the object remains in the region. If you set the
value as 0 s, the alarm is triggered immediately after the object enters the region.
The range is between 0 and 2.
The sensitivity value defines the size of the object that can trigger the alarm. When
the sensitivity is high, a small object can trigger an alarm. The range is between 1
and 100.
To draw a new rectangle, if required, select another region number from the drop-
down list and then draw the region and set its threshold and sensitivity values.
5. Select the arming schedules for the VCA event.
Click the Arming Schedule tab. Select the day of the week and the time periods
during the day when intrusion can be detected. The configuration is the same as
that for motion detection (see “Motion detectionon page 22). You can schedule
only one time period in a day. Default is 24 hours. Click Save to save the settings.
Click Copy to copy these settings to other days of the week.
Click Save to save the settings. Click Copy to copy these settings to other days of
the week.
6. Select the response method to the VCA event.
Click the Actions tab. Under Alarm Linking, check one of more of the desired
response method: