TruVision High Definition TVI Vandal Dome Installation Guide TVD-2402/TVD-4402 TVD-2404/TVD-4404 TVD-2405/TVD-4405 P/N 1073166-EN • REV A • ISS 31MAR16
Installation Guide
Content Product overview 4 Camera description 6 Installation 9 Operating temperature range 14 Program 14 Setup menu 19 Specifications 21 Legal and Regulatory information 23 Installation Guide 3
Product overview This is the Installation Guide for the TruVision High Definition TVI dome TVD-2402/TVD-4402,TVD2404/TVD-4404 and TVD-2405/TVD-4405. This guide describes a standard installation.
Hex wrench Monitor output cable Spare rubber knockout Installation Guide • WEEE and Battery Disposal sheets There is a rubber knockout on the camera back box. This is for future use.
Camera description TVD-2402/TVD4402: 1. 2. 3. 4. 5. 6 Dome liner Bubble Lens Power cable CVBS video output cable (black) 6. TVI video output cable (grey) 7. Back box 8. Switch (Left = WDR / Right = CVBS) 9. Menu button 10.
TVD-2404/4404 and TVD2405/4405: 1. 2. 3. 4. 5. Dome liner Bubble Lens Power cable CVBS video output cable (black) Installation Guide 6. TVI video output cable (grey) 7. Back box 8. Switch (Left = WDR / Right = CVBS) 9. Menu button 10.
Note: Please check the camera output settings before setting up a system. The TVI video output can be only connected to DVR with TVI signal input. The CVBS output supports a standard CVBS monitor (or test monitor), an encoder or a DVR. For 720P Dome cameras TVD-2402/TVD4202, the CVBS and TVI output can not be used at the same time. Use the built-in switch to select the camera video output.
Installation To install the camera on a ceiling: 1. Using the template, place it level against the mounting surface and mark the position of the mounting holes. 2. Following all local safety regulations, drill and prepare the mounting holes. 3. Remove the camera from its back box. 4. Loosen the three screws on the edge of the bubble with the supplied hex wrench. 5. Remove the bubble and the dome liner.
6. Secure the back box to the ceiling with the supplied screws. Note: Please remove the rubber knockout for cable routing outside of the camera, when required.
7. Using a 75-ohm coaxial video cable, connect the camera TVI video output to a TVI DVR, and connect a 12 VDC or 24 VAC power supply to the power cable. 8. Align the camera with the back box and tighten the screws to fasten the camera to the back box. 7. Adjust the surveillance angle: 1) View the camera image on a monitor.
2) Rotate the camera block to adjust the pan direction [0 to 355°]. 3) Loosen the tilting lock screw. 4) Rotate the camera block to adjust the tilt direction [0 to 90°]. 5) Tighten the tilting lock screw. 6) Rotate the camera lens holder [0 to 355°] to adjust the lens to the surveillance angle. ~ ~ ~ 8. Zoom and focus adjustment a) Manually adjust the zoom and focus of TVD2402/TVD-4402 and TVD-2404/TVD-4404. 1) 12 View the camera image using the monitor.
2) Loosen the zoom lever and move the screw between T (Tele) and W (Wide) to obtain the appropriate angle of view. 3) Tighten the zoom lock screw. 4) Loosen the focus lever and move the screw between F (Far) and N (Near) to obtain the optimum focus. 5) Tighten the focus lock screw. Zoom b) Focus TVD-2405/TVD-4405 has a motorized lens. Adjust its zoom and focus by using the zoom and focus buttons on the PTZ panel of a connected recorder or TVS-C200 controllor.
Operating temperature range The operating temperature of the TVD-2402/4402 and TVD-2404/4404 cameras is -30 to +60 °C (-22 to +140 °F). When the camera initially starts up, the heater will start to work automatically when the temperature is below -10 °C (14 °F). However, with continuous operation the heater will not work until the internal temperature drops below -30°C (-22 °F). It will then be disabled when the temperature reaches -10 °C (14 °F). The heater only works under 24 VAC.
Using the camera buttons Please press the Menu button to call up the OSD menu and select an OSD item. Press the button up/down to move the cursor up or down to an OSD item. Press the button left/right to move cursor left or right to adjust the value of a selected OSD item. Using a TVI output Once the camera hardware has been installed, you can configure the camera settings on the TVI DVR. Connect the TVI cable to the DVR, as shown below.
Access the PTZ menu of the connected DVR, set the TruVision-Coax protocol and use the PTZ control panel to configure the camera. Click Iris+ to access to the camera OSD menu and select an OSD item. Click the directional buttons UP or DOWN to move the cursor up or down to an OSD item. Click the directional buttons LEFT or RIGHT to move cursor left or right to adjust the value of a selected OSD item. Note: The TVD-2405/TVD-4405 camera has a motorized lens.
Press the OK button of the TVS-C200 for a few seconds until you see the OSD menu display on the monitor. The OK button is also used to select an OSD item. Use the directional buttons to move the cursor and change a value. For more details, refer to the TVS-C200 user manual. TVD-2402/TVD-4402 The camera has CVBS and TVI dual video outputs. Set the built-in switch to CVBS for viewing the program on a standard monitor.
The TVI signal is blocked until the camera configuration is complete and the switch is reset to TVI. TVD-2404/TVD-4404 and TVD-2405/TVD-4405 The camera has the CVBS and TVI dual video outputs. The built-in switch is for WDR/CVBS selection. Set the built-in switch to CVBS to view the setup menu on a standard monitor. When the programing is finished, you can change the switch setting to WDR to enable the WDR feature. In such case, the CVBS output will be disabled.
Setup menu TVD-2402/TVD-4402: Installation Guide 19
TVD-2404/TVD-4404, TVD-2405/TVD-4405: 20 Installation Guide
Specifications Power supply 24 VAC/12 VDC Current TVD-2402/ TVD-4402: 12 VDC: 300 mA max. 24 VAC: 210 mA max. TVD-2404/TVD-4404: 12 VDC: 375 mA max. 24 VAC: 270 mA max. TVD-2405/TVD-4405: 12 VDC: 1 A max. 24 VAC: 500 mA max. Power consumption TVD-2402/ TVD-4402: 12 VDC: 3.5W max. 24 VAC: 5 W max. TVD-2404/TVD-4404: 12 VDC: 4.5 W max. 24 VAC: 6.5 W max. TVD-2405/TVD-4405: 12 VDC: 12 W max. 24 VAC: 12 W max. Weight (net) 641 g / 1.41 lb. (without back box) 932 g / 205 lb.
Dimensions 22 Ø145.3 x 124.2 mm (Ø 5.72 x 4.89 in.
Legal and Regulatory information Copyright: © 2016 United Technologies Corporation, Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved. Trademarks and patents: Trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Manufacturer: Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative: UTC Fire & Security B.
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ACMA compliance Notice! This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Canada This Class A digital apparatus complies with Canadian ICES-003.