TruVision High Resolution TVI Box Camera TVC-2401 / TVC-4401 Installation Guide P/N 1073165-EN • REV A • ISS 04APR16
Content Product overview 2 Camera description 3 Installation 5 Programming 7 Setup menu 9 Specifications 10 Legal and regulatory information 10 Installation Guide 1
Product overview This is the Installation Guide for TruVision High Resolution TVI Box Camera TVC-2401/TVC-4401. This guide describes a standard installation.
WEEE disposal CD Camera description 1. Lens mounting ring 2. CVBS output 3. TVI output 4. Menu button 5.
. GND 7. 12 VDC / 24 VAC 8. Alarm, RS-485, D/N port 1 2 1. Lock screw 2. Auto-iris drive interface Auto iris connector The auto iris connector is composed of four square pins as shown below. Damp+, Damp-, Drive+ and Drive- pins are used in DC driven mode.
No. DC 1 Damp- 2 Damp+ 3 Driver- 4 Driver+ Installation Refer to the instructions that came with the lens you purchased for complete lens installation instructions. The camera automatically detects the type of lens used. Note: For optimal performance, an auto iris lens is recommended. To attach the lens: 1. If a C-mount lens is used, the supplied CS adaptor must be fitted to the lens mounting ring or the sensor/filter may be damaged 2.
3. Connect the lens auto iris wire to the auto iris connector of the camera. To mount the camera: 1. Attach the camera to a mounting bracket using appropriate fasteners or install the camera in an appropriate outdoor housing. 2. Adjust the camera to get an optimum angle. 3. Tighten the screw to secure the camera to the bracket, if required. To finish the installation: 1. 6 Using a 75-ohm coaxial video cable, connect the camera TVI video output to a TVI DVR.
2. Connect the service monitor CVBS connector to the camera CVBS output, if required. Please refer to the Programming section for more information. 3. Power the camera with a power supply. Please mind the polarity of 12 VDC connections. 24 VAC connections are not polarity sensitive. 4. Finish the installation by adjusting zoom and focus to get a clear picture. Programming Program using a TVI output Once the camera hardware has been installed, you can configure the camera settings on the TVI DVR.
Please select the PTZ protocol as TruVision Coax and click the menu button to call up the camera menu. For more details, please see the TVI DVR user manual. The camera has CVBS and TVI dual video outputs. When the WDR feature is enabled via the OSD, the CVBS output will be blocked.
Setup menu Installation Guide 9
Specifications Power supply 24 VAC / 12 VDC Current 1 A max. Power consumption 12 W max. Weight (net) 0.83 lb. (378 g) Dimensions 2.7 x 2.3 x 5.85 in. (69.2 × 57.3 × 148.7 mm) Legal and regulatory information Copyright: © 2016 United Technologies Corporation, Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
Manufacturer: Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands Certification: FCC compliance: Class A Class A: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
European Union directives: 12004/108/CE (EMC directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.