Installation Instructions
Table Of Contents
- Introduction
- Installation
- Wiring
- DIP switch options
- Initial power up
- Pattern adjustment
- Operation
- FCC compliance
- Specifications
- Product ordering
RCR-REX Request-to-Exit Dual Technology Motion Sensor
Installation Instructions
6
Mask installation
The RCR-REX has a mask included that allows you to adjust the
PIR field of view. This may be necessary for some installations
when the unit may be tripped by non-exiting foot traffic or other
erroneous sources that are with the detection area.
To install the mask, do the following:
1. Remove the appropriate segments of the mask to include the
desired area of detection.
2. Open the RCR-REX cover and locate the PIR lens.
3. Slip the mask into the two side brackets that hold the PIR
lens in place (Figure 15). Be careful not to dislodge the lens.
4. Close the cover.
Figure 15. Mask installation
FCC compliance
This device complies with Part 15 of the FCC rules. Operation is
subject to the following three conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired operation.
3. Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
FCC ID: CGGAA2
Specifications
Product ordering
The equipment should be installed in accordance with the National Electrical
Code, ANSI / NFPA70.
Side bracket
Side bracket
Lens
Lens holder
Voltage 12 to 30 VDC or VAC, 60Hz
Current 23mA typical, 27mA maximum at 12 VDC
15mA typical, 17mA maximum at 24 VDC
31mA typical, 38mA maximum at 12 VAC
26mA typical, 29mA maximum at 24 VAC
Time delay 1/2, 1, 2, 4, 8, 16, 32, 64 seconds ± 10%,
selectable
Alarm output DPDT (2 Form C)
Maximum loop rating 2 A at 30 V AC/DC
Loop type Closed, open
Tamper output 50 mA at 30 VDC
Wire gauge AWG 14 to 22 (18 to 22 recommended)
Operating temperature -20 to 122°F (-29 to 50°C)
Relative humidity 10 to 95% non-condensing
RFI immunity 20V/meter from 80 MHz to 1 GHz
Static immunity 8k V
Lightning immunity 2.4kV, 1.4 Joules
Radar frequency 5.84 GHz
Range
Depth
Width
3 to 15 ft. (0.9 to 4.57 m)
7.9 ft. (2.4 m)
Mounting height 7 to 15 ft. (2.13 to 4.57 m) typical
Dimensions (W x H x D) 7.4 x 1.76 x 1.85 in. (187.8 x 44.7 x 47 mm)
Color Off-white, black, gray
Listings C UL-US
Industry Canada
CE (pending)
FCC
Product Description
RCR-REX-W RCR-REX request-to-exit dual technology
motion sensor, off-white
RCR-REX-B RCR-REX request-to-exit dual technology
motion sensor, black
RCR-REX-G RCR-REX request-to-exit dual technology
motion sensor, gray
Technical support
Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada).
Outside the toll-free area: Contact your local dealer.
www.gesecurity.com