Testing
This section explains how to test the operation of the
wireless devices that you programmed into the Quik
Bridge Two-Channel Receiver.
General procedure for testing the Quik Bridge Two-
Channel Receiver:
CAUTION: To avoid sending false alarms to the
police or fire department when test-
ing monitored systems, always call
and notify the central station before
activating alarms.
1) For monitored systems, call the central station or
other monitoring service to let them know you
will be testing the system.
2) From the panel, exit programming mode.
3) Arm the panel.
4) Trip a wireless sensor or other device that you
added to the receiver.
5) Restore the sensor to a non-alarm state, and dis-
arm the system. Repeat steps 4 and 5 for each
wireless device.
6) Test each button mode on each Keychain Touch-
pad you added to the receiver.
7) If necessary, call the central station and let them
know you finished testing the system.
Specifications
Dimensions: 2.5 × 2.6 × 0.9'' (64 × 66 × 23 cm)
Maximum current draw (both relays on): 70 m A
Operating temperature range: 40 to 120°F (4 to 49°C)
Power requirements: 11 to 15 VDC
Receiver frequency: 319.5MHz
Receiver range: 250 feet (76 meters) minimum in open
air
Receiver type: Super regenerative
Relay contact rating:
Current: 7A maximum
Voltage: 250VAC maximum
Contact: Dry contact Form C