Installation Manual
Page 11
Quik Bridge ® Two-Channel Receiver
Setting up Garage Door Opener
Control
Note: The Quik Bridge Two-Channel Receiver is a
super regenerative receiver. To ensure consis-
tent operation of the receiver, mount it at least
three feet away from other super regenerative
receivers (such as the receiver in most garage
door openers).
To set up garage door opener control:
1) Program button mode H (for zon e1) o rL (for
zone 2) into the desired zone of the receiver (see
Table 3).
2) Using Figure 7 as a guide, connect the garage door
opener wires to the appropriate receiver zone out-
put.
Figure 6. Wiring a receiver zone output to the
terminals of a garage door opener
Connecting the Receiver to a Con-
trol Panel
Using Figures 7 and 8 as guides, connect the receiver
zone output terminals to the panel zone input termi-
nals. Each zone may be configured to be N/C (Nor-
mally Closed) or N/O (Normally Open).
Figure 7. Wiring a receiver zone to be N/C
Figure 8. Wiring a receiver zone to be N/O
9217G14B.DSF
5
12
ZONE 1 N/O
ZONE 1 COMMON
ZONE 1 N/C
+11–15 VDC
GROUND
RECEIVER ZONE
OUTPUT TERMINALS
ZONE 2
GARAGE
DOOR OPENER
TERMINALS
34
8
76
9217G05B.DSF
PANEL
ZONE INPUTS
678
12
ZONE 1 N/O
ZONE 1 COMMON
ZONE 1 N/C
+11–15 VDC
GROUND
RECEIVER ZONE
OUTPUT TERMINALS
ZONE 2
RETURN
ZONE #
+11–15 VD
C
GROUND
4
3
5
9217G06B.DSF
5
12
ZONE 1 N/O
ZONE 1 COMMON
ZONE 1 N/C
+11–15 VDC
GROUND
RECEIVER ZONE
OUTPUT TERMINALS
ZONE 2
RETURN
PANEL
ZONE INPUTS
GROUND
+11–15 VD
C
ZONE #
4
876
3