PROGRAMMING WORKSHEETS
LOC DESCRIPTION
0 Account Code (from provider) Default: AAAAAA
Partition Event Enables 1
1 - Partition 1
2 - Partition 2
3 - Partition 3
4 - Partition 4
5 – Partition 5
6 – Partition 6
7 – Partition 7
8 – Partition 8
Transmission Format 2
0 - Contact ID
1 - SIA
2 - 4+2
Events That Can Be Enabled During Phone Fault (8 segments)
Segment 1
1 - Alarm
2 - Restore
3 - Shunt
4 - Shunt Restore
5 - Tamper
6 - Tamper Restore
7 - Trouble
8 - Trouble Restore
Segment 2
1 - Sensor Low Battery
2 - Sensor Low Batt Restore
3 - Sensor Missing
4 - Sensor Missing Restore
5 – 8 Reserved
Segment 3
1 - Reserved
2 - Reserved
3 - Duress
4 - Auxiliary 1
5 – Auxiliary 2
6 - Holdup (Silent Panic)
7 - Keypad Panic
8 - Keypad Tamper
Segment 4
1 - Box Tamper
2 - Box Tamper Restore
3 - AC Fail
4 - AC Restore
5 - Low Battery (system)
6 - Low Battery Restore
7 - Fuse (over current)
8 - Fuse (over current)
Restore
Segment 5
3
1 - Siren Tamper
2 - Siren Tamper Restore
3 - Phone Line Monitor
4 - Phone Monitor Restore
5 - Expander Trouble
6 - Exp. Trouble Restore
7 - Fail to Communicate
8 - Log Full