Installation Manual

5
WIRE REQUIREMENTS
Table 2.1
Wire Gauge Length
(Feet)
Connected to NX8/NX8E Connected to NX-320
250 24 24
500 24 22
1000 22 20
2000 20 16
2500 18 16
PROGRAMMING THE NX582-E
USING THE LED KEYPAD
Entering the Program Mode
To enter the Program Mode, press [r]-[8]. At this time, the five function
LEDs (Stay, Chime, Exit, Bypass, & Cancel) will begin to flash. Next, enter
the "Go To Program Code" (Factory Default is [9]-[7]-[1]-[3]). If the "Go To
Program Code" is valid, the "Service" LED will flash and the five function
LEDs will illuminate steady. You are now in the Program Mode and ready to
select the module to program.
# Select the Module to Program
All modules connected to the NX8/NX8E are programmed through the
keypad. Enter the address of the NX582-E, which is [7]-[7], followed by [#].
The Armed LED will illuminate while it is waiting for a programming location
to be entered. Other module entry numbers can be found in their
corresponding manuals.
# Programming a Location
Once the number of the module to be programmed has been entered, the
"Armed" LED will illuminate, indicating it is waiting for a programming
location to be entered. Any location can be accessed by directly entering the
desired programming location followed by the pound [#] key. If the location
entered is a valid location, the "Armed" LED will extinguish, the "Ready" LED
will illuminate and the binary data for the first segment of this location will be
shown by the zone LED's. While entering new data, the "Ready" LED will
begin flashing to indicate a data change in process. The flashing will
continue until the new data is stored by pressing the [r] key. Upon pressing
the [r] key, the keypad will advance to the next segment and display its