Owner manual

NX-1710E Single Door Control
7
V. ADDRESSING
The first thing that must be decided is the address of this particular relay/output module. This is the address that
will be selected when programming the auxiliary devices. To set the addresses use the table below. Refer to
Table V-1 that follows for possible addresses.
The door control unit must be powered down and powered back up in order to read
new or modified dip switch settings.
Table V-1
Bus Address Dip Switch Setting Bus Address Dip Switch Setting
1 2 3 4 1 2 3 4
128 136 ON
129 ON 137 ON ON
130 ON 138 ON ON
131 ON ON 139 ON ON ON
132 ON 140 ON ON
133 ON ON 141 ON ON ON
134 ON ON 142 ON ON ON
135 ON ON ON 143 ON ON ON ON
VI. PROGRAMMING
USING THE LED KEYPAD
ENTERING THE PROGRAM MODE
Enters the Program Mode.
Stay, Chime, Exit, Bypass & Cancel LEDS
will flash.
[Go To Program Code]
Factory Default is 
If the "Go To Program Code" is valid, the
"Service" LED will flash and the five function
LEDs will illuminate steady. You are now in the
Program Mode and ready to select the module
address.
ENTERING THE MODULE ADDRESS
Scan a card.
 #
(example only)
Enter the module address. Refer to Table V-1
for the address.
The Armed LED will illuminate while it is
waiting for a programming location to be
entered.
LOADING THE FACTORY DEFAULTS (USER PROGRAMMING ONLY)
 #
The keypad will beep 3 times indicating that
the loading is in progress. The loading takes
about 6 seconds.
DEFAULTING THE CARD SERIAL NUMBERS
 #
The keypad will beep 3 times indicating that
the loading is in progress.