Owner manual

NX-1710E Single Door Control
19
LOCATION 54 WEIGAND FORMAT 1 – PARITY TYPE 4
(1 segment of decimal data) This location programs the Partity Type 4 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
LOCATION 55 WEIGAND FORMAT 1 – PARITY MASK 4
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 54 (Parity Type 4). The factory default is:
Seg 1 Seg 2 Seg 3 Seg 4 Seg 5 Seg 6 Seg 7 Seg 8
-------- -------- -------- -------- -------- -------- -------- --------
LOCATION 56 WEIGAND FORMAT 1 – PARITY TYPE 5
(1 segment of decimal data) This location programs the Partity Type 5 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
LOCATION 57 WEIGAND FORMAT 1 – PARITY MASK 5
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 56 (Parity Type 5). The factory default is:
Seg 1 Seg 2 Seg 3 Seg 4 Seg 5 Seg 6 Seg 7 Seg 8
-------- -------- -------- -------- -------- -------- -------- --------
LOCATIONS 58 – 70 WEIGAND FORMAT 2 (TECOM ASC 27 BIT)
These locations contain the programming for Weigand Format 2. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 71 - 83 WEIGAND FORMAT 3 (HID1000)
These locations contain the programming for Weigand Format 3. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 84 – 96 WEIGAND FORMAT 4 (H10304)
These locations contain the programming for Weigand Format 4. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 97 - 109 WEIGAND FORMAT 5 (40 BIT W/FACILITY CODE CASI 4001)
These locations contain the programming for Weigand Format 5. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 110 - 122 WEIGAND FORMAT 6 (40 BIT W/O FACILITY CODE CASI 4002)
These locations contain the programming for Weigand Format 6. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 123 - 135 WEIGAND FORMAT 7 (UNDEFINED)
These locations contain the programming for Weigand Format 7. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 136 - 148 WEIGAND FORMAT 8 (UNDEFINED)
These locations contain the programming for Weigand Format 8. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.