Owner manual
NX-1710E Single Door Control
18
USER-DEFINABLE FORMATS
The following locations are considered to be advanced programming and should
ONLY be used by installers with a thorough understanding of Weigand Formats. Do
not attempt to program these locations if you are not familiar with Weigand packets.
LOCATION 45 WEIGAND FORMAT 1 (STANDARD 26 BIT) – DIGITS & BITS
(5 segments of decimal data) This is the first location used to program the Weigand Format 1. (Loc 45-57)
Segment 1 Number of digits in Facility Code
Segment 2 Number of digits in Badge Number
Segment 3 Number of bits in Facility Code
Segment 4 Number of bits in Badge Number
Segment 5 Total number of bits in complete format (including parity bits)
LOCATION 46 WEIGAND FORMAT 1 – BIT DESCRIPTORS (BITS 1-32)
(32 segments of hex data) This location contains the descriptors for bits 1 – 32 of Weigand Format 1. The
available options are: 0=Always Zero; 1=Always One; B=Badge number; D=Parity bit; E=End of
format; F=Facility Code bit. Segment 1 = Bit Descriptor 1; Segment 32 = Bit Descriptor 32.
LOCATION 47 WEIGAND FORMAT 1 – BIT DESCRIPTORS (BITS 33-64)
(32 segments of hex data) This location contains the descriptors for bits 33 – 64 of Weigand Format 1.
The available options are: 0=Always Zero; 1=Always One; B=Badge number; D=Parity bit; E=End of
format; F=Facility Code bit. Segment 1 = Bit Descriptor 33; Segment 32 = Bit Descriptor 64.
LOCATION 48 WEIGAND FORMAT 1 – PARITY TYPE 1
(1 segment of decimal data) This location programs the Partity Type 1 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 1.
LOCATION 49 WEIGAND FORMAT 1 – PARITY MASK 1
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 48 (Parity Type 1). The factory default is:
Seg 1 Seg 2 Seg 3 Seg 4 Seg 5 Seg 6 Seg 7 Seg 8
12345678 12345678 12345678 ------78 -------- -------- -------- --------
LOCATION 50 WEIGAND FORMAT 1 – PARITY TYPE 2
(1 segment of decimal data) This location programs the Partity Type 2 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 2.
LOCATION 51 WEIGAND FORMAT 1 – PARITY MASK 2
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 50 (Parity Type 2). The factory default is:
Seg 1 Seg 2 Seg 3 Seg 4 Seg 5 Seg 6 Seg 7 Seg 8
12345678 ---45678 -------- -------- -------- -------- -------- --------
LOCATION 52 WEIGAND FORMAT 1 – PARITY TYPE 3
(1 segment of decimal data) This location programs the Partity Type 3 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
LOCATION 53 WEIGAND FORMAT 1 – PARITY MASK 3
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 52 (Parity Type 3). The factory default is:
Seg 1 Seg 2 Seg 3 Seg 4 Seg 5 Seg 6 Seg 7 Seg 8
-------- -------- -------- -------- -------- -------- -------- --------