Owner manual

NX-1710E Single Door Control
12
Segment 4 LED1 (Green) Options:
LED1 - "On" to follow Ready status of system. (Default is “On”)
LED2 - "On" to toggle with the relay activation. (Default is “On”)
LED3 - "On" if inverted.
LED4–8 Reserved.
Segment 5 LED2 (Red) Options:
LED1 - "On" to follow Armed status of system. (Default is “On”)
LED2 - "On" to toggle with the relay activation.
LED3 - "On" if inverted.
LED4–8 Reserved.
Segments 6 – 8 Reserved
LOCATION 1 READER “B” SCAN FUNCTIONS & OPTIONS
(8 segments of binary data) Location 1 is used to select the particular function(s) that are activated when a card
is scanned at Reader “B”. More than one function may be selected. If more than one function is selected, they
will execute in order from function 1 to function 8.
Functions 1-6 will be performed based on the user’s authority as programmed by the [] [6]
function (refer to keypad user manual).
Segment 1 Single Scan Function
Program the functions that are performed when a card is scanned {one beep}.
LED1 - "On" to send Code Entry function to the control panel.
LED2 - "On" to activate the Armed Away mode.
LED3 - "On" to activate the Armed Stay mode.
LED4 - "On" to send the Disarm function to the control panel.
LED5 - "On" to send Auxiliary Function #1 to the control panel.
LED6 - "On" to send Auxiliary Function #2 to the control panel.
LED7 - "On" to broadcast an X-10 function (see Location 241 for programming).
LED8 - "On" to send a Request-to-Exit (RTE); and to activate the onboard relay. (Default
is “On”)
Segment 2 Triple Scan Function
Program the functions that are performed when a card is scanned three times {three beeps}. The descriptions
of the options are the same as for Single Scan Function (Segment 1 above). Default is 1.
Segment 3 Reader Options:
LED1 - "On" if tamper is inverted.
LED2 - "On" if tamper is enabled.
LED3 - "On" if reader buzzer is to follow typical keypad buzzing.
LED4 - "On" if reader automatically issues a beep when the card is scanned. Enabling
this option prevents the door control from issuing another beep. (Default is “On”)
LED5 - “On” if LEDs to extinguish after 2 minutes without a scan. (Note: This option doesn’t
disable the flashing green LED during card programming.)
LED6–8 Reserved.
Segment 4 LED1 (Green) Options:
LED1 - "On" to follow Ready status of system. (Default is “On”)
LED2 - "On" to toggle with the relay activation. (Default is “On”)
LED3 - "On" if inverted.
LED4–8 Reserved.