Installation Guide Owner manual
21-3602E rev1.5 Monitor xL™ Advanced Installation Guide 53
R00107 Keypad Selections
(left to right on keypad screen) Example:
Default Name Selections Description
04 Unlock Time 00-31 (Delay Table)
04 = 5 Sec
The unlock duration when a user is
granted entry.
06
Challenged Unlock
Time
00-31 (Delay Table)
06 = 15 Sec
The unlock duration when access is
granted for a physically challenged user.
Whether or not the 'Challenged' unlock
time applies is based on the 'Challenged'
setting for the user. For details, refer to
U00102 (User Name and Basic
Settings)
0
Door Alarm
Monitoring
0=None
1=Door Held Open Processing, 2=Door
Forced processing,
3=Door Held
Open and Door Forced
Processing
Whether or not this door is to be
monitored for forced entry and/or being
held open too long.
(yes)
Reader LED Mode
= BiColor = Normal
Set this as yes for arming stations,
and for any readers with a bicolour LED.
(no)
RTE Required
(request to Exit)
(yes) □ (no)
Whether or not the RTE input will be
used / monitored.
(no)
Panel Process RTE
(yes) □ (no)
Sets the main panel to control RTE pro-
cessing instead of the door controller
(no)
Do Not Unlock Door
On Process RTE
(yes) □ (no)
This setting is used with "Interlocked"
doors that are equipped with an RTE
button e.g. PIR RTE. For details on the
'interlock' feature, refer to R00111
(no)
Log RTE
(yes) □ (no)
Whether 'RTE presses' are to be
recorded.
(no)
Turn Style
(yes) □ (no)
Escort can use card 2
n
d
time to enter
after using once to validate at Anti-Pass
Back door.
(no)
Entry Detection
(yes) □ (no)
Second try at Anti-Pass Back door if first
unlock missed. I.e. door was not opened
at 1
st
unlock.
RTE = “Request to Exit”
04· 06· 0·
·
Save R00107