Installation Guide Owner manual

50 Monitor xL™ Advanced Installation Guide 21-3602E rev1.5
T08001 How the input will behave when it is active.
Keypad Selections (left to right on keypad screen)
Default Name Selections Description
(no)
Transmit in OFF
(yes) (no)
Reporting to the Monitoring Station
(no)
Transmit in STAY
(yes) (no)
Reporting to the Monitoring Station
(no)
Transmit in ON
(yes) (no)
Reporting to the Monitoring Station
(UK ACPO custom point # 2 = yes)
(no)
Sonalert in OFF
(yes) (no)
Keypad sounder active.
(UK ACPO custom point # 2 = yes)
(no)
Sonalert in STAY
(yes) (no)
Keypad sounder active.
(no)
Sonalert in ON
(yes) (no)
Keypad sounder active.
(no)
Siren in OFF
(yes) (no)
System siren active.
(no)
Siren in STAY
(yes) (no)
System siren active.
(no)
Siren in ON
(yes) (no)
System siren active.
Default UK ACPO Custom Input Settings (T08000 and T08101)
Custom
Input Pt.
Level
Characteristic
Type
Class Bypass
Chime Pre-Alarm
T080
0 40 6
(no) (no) (no)
T081
0 10 5
(no) (no) (no)
Custom
Input Pt.
Transmit
OFF
Transmit
STAY
Transmit
ON
Sonalert
OFF
Sonalert
STAY
Sonalert
ON
Siren
OFF
Siren
STAY
Siren
ON
T080
(no) (no) (no) (no) (no) (no) (no) (no) (no)
T081
(no) (no)
(yes) (yes)
(no) (no) (no) (no) (no)
Program Section: R001 (Doors)
WARNING: R00100 – R00114 Access Control related selections are only available with the addition of
the “Feature Expansion Board
”.
R00100 Keypad Selections
(left to right on keypad screen) Example:
Default Name Selections Description
00
Access Module
Number
00 = Door undefined
01-24=Access Pod Module #
The door controller module associated
with this reader/door.
blank
Door Name 12 alpha-numeric characters
A suitable name/description for this
reader/door.
1
Module Door
Port Number
1 or 2
The 1st or 2
nd
door on the door controller
module. This is indicated on the PCB.
Tip: This is 1 for odd-numbered doors,
and 2 for even-numbered doors.
Note: The second door on each door controller module is configured separately (typically R002, R004, etc.).
00· Door Name
1
Save R00100