Installation Guide Owner manual
21-3602E rev1.5 Monitor xL™ Advanced Installation Guide 39
Output Selections Table
WARNING: Access Control related outputs can only be used
with the addition of the “Feature Expansion Board
”.
Program Section (“q”)
“S”ystem
Section Range (“nnn”)
000 – 000
Code “cc”
Description
00 Fallback sonalert (at control panel) if
Module Bus fails. Provides 1 sec. Output
every 8 sec. And activates if there is no
operational keypad in an area with
programmed keypads.
01 Not Used
02 When system is FULLY ON
03 PARTIALLY ON. One or more areas
ON.
04 When system is FULLY OFF
05 When system is IN ALARM - resets
when point(s) restore
(includes pseudos & tampers)
06 Follows ALARM (BURG / EMERG) &
FIRE siren steady.
07 Follows ALARM siren - steady for BURG
/ EMERG. Keypad tone & siren is 1 sec
on/off for FIRE.
For UL: When using this output type,
fire siren is ½ sec on/off three times, 1.5
sec pause, and repeats. Keypad tone is
1 sec on/off.
08 Follows ALARM siren - steady for BURG
/ EMERG and provides 2 sec on/off for
FIRE
09 Digital PHONE LINE trouble (follows
report delay or line failure)
10 System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off then back on again)
11 When there is a point BYPASSED
somewhere in the system
12 When any ‘FIRE’ point is in alarm
13 When any ‘HOLD UP’ point is in alarm
14 When any ‘Aux Alert' point is in alarm
15 When any ‘VAULT / SAFE’ type point is
in alarm
16 When any ‘'Burglary' point is in alarm.
Delayed burglary for European
Version.
17 When any ‘Supervisory' point is in alarm.
18 When any 'Pseudo' is in alarm
19 Pseudo 1 – System Trouble / All type
tamper for European Version.
20 Pseudo 2 – Battery Trouble
21 Pseudo 3 – AC (Mains) Trouble
22 Pseudo 4 – Phone Trouble
23 Pseudo 5 – Report Delay
24 Pseudo 6 – Time Lost
25 Pseudo 7 – Time Change
26 Pseudo 8 – Program Change
27 Pseudo 9 – Program Error
28 Pseudo 10 – Fuse Failure
29 Pseudo 11 – Module Trouble
30 Pseudo 12 – Module Battery Low
31 Pseudo 13 – Module Program Edit
32 Pseudo 14 – Module Program Error
33 Pseudo 15 – Misc. Trouble
34 Pseudo 16 – SIP Trouble
35 Duress Pin
36 Doors Unlocked.
37 Doors Locked Out
38 Doors Held Open
39 Doors Forced
40 Doors Tamper (door contact condition:
no EOL resistor etc.)
41 Doors Open
42 Doors Secure
43 Doors Sensor Trouble (magnetic bond
sensor not ok)
44 Global Invalid PIN and / orCard lockout.
45 Host (Director) computer is On-Line.
46 Host (Director ) computer is Off-Line.
Response time for IP, external modem,
direct connection is 2 min. Bell 103 is 1
min.
47 SIP On-Line.
48 SIP Off-Line. Response time is 3
minutes.
49 Any point in tamper.
50 Any point in Alarm.
51 Any area is Force Arming
52 Any area Failed to Close
53 Phone Line Failure
54 Local AC (mains) failure.
55
System Tamper – European Version.
56
System Fault – European Version.
57 System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off)
58 Bypass is in effect in any armed area.
European Version (System)
59 Fire
60 Personal Attack
61 Unconfirmed Alarm
62 Area Set / Unset
63 Freezer / Fire Fault
64 Bypass in Effect
65 Confirmed Alarm
66 Siren
67 Confirmed Alarm (Strobe)
System Special Outputs. Section Range: 001 – 001. See
examples 8 & 9 in Output Examples. NOTE: Only
configurable through the Director Software.
00 1 sec on, 1 sec off
01 2 seconds on every minute
02 10 seconds on every minute