User Manual
Table Of Contents
- Preface
- Chapter 1 KTD-405/405A/405-2D overview
- Chapter 2 Installation
- Chapter 3 Programming
- Programming modes
- Supervisor programming
- Figure 17. Supervisor programming menu tree
- Figure 18. KB3 PTZ PROTOCOL display
- Figure 19. ENTER REMOTE PRGMG display
- Figure 20. KEYPAD TITLE display
- Figure 21. KEYPAD LOCKOUT PRIORITY displays
- Figure 22. Lowest user programmed preset menu
- Figure 23. PROGRAM SOFT KEYS display
- Figure 24. PRESS KEY TO PROGRAM display
- Figure 25. Command selection display
- Figure 26. Confirm command selection display
- Figure 27. CHANGE ACCESS CODES displays
- Figure 28. BAUD RATE display
- Figure 29. SYSTEM CONTROL display
- Figure 30. INACTIVE TIMEOUT display
- User programming
- Figure 31. OPERATING MODE menu
- Standard Digiplex menus
- Zone menus
- Figure 38. OPERATING MODE menu
- Figure 39. Zone menu
- Figure 40. ENTER ZONE ADDRESS menu
- Figure 41. ZONE xx TITLE menu
- Figure 42. SEND TO ALL KEYPADS display
- Figure 43. Zone hub display
- Figure 44. Zone monitor outputs
- Figure 45. Zone camera inputs
- Figure 46. Access restriction menus
- Figure 47. ZONE xx ACCESS menu
- Figure 48. Annunciation menu
- Figure 49. Call tone menu
- Figure 50. SPOT MONITOR NUMBER menu
- Remote programming
- Chapter 4 Operation
- Operating your keypad
- Standard Digiplex mode
- Figure 55. Normal operating display
- Selecting a monitor
- Selecting a camera
- Controlling a camera
- Setting a preset
- Recalling a preset
- Operating group switching on Digiplex IV switchers
- Setting autopan limits
- Controlling a DVMRe/multiplexer (hybrid mode)
- Controlling a recording device
- System information menus
- Help menu
- Audio
- Zone mode
- Chapter 5 Troubleshooting and support
- Appendix A Sample configurations and charts
- Sample analog system configurations
- Sample IP system configuration
- Receiver site addressing
- Reprogrammable keys and commands
- System planning chart
- Index
KTD-405/KTD-405A/KTD-405-2D Controller Keypad
User Manual
16
Connecting multiple keypads with STP cable
Adhere to all installation guidelines while making connections, including your local codes and those provided
in Installation guidelines on page 8
Figure 11. KTD-405 and KTD-405A connections via STP cables
12 VDC (observe polarity, if provided transformer and plug not used)
RS-485 to I/O box of additional keypad via STP cable (with floating shield)
RS-422 IN (data in from devices such as alarm units, ASCII converters, or keypads (see guidelines))
RS-422 OUT (data out to devices such as domes, switchers, other keypads (not KTD-405s))
AUDIO OUT (to speaker and speaker shield)
RS-485 OUT (data out to devices such as multiplexers or DVMRe’s; ground at mux/DVMRe)
Note: When using STP for the RS-485 connection between I/O boxes, you can use only one of the two RJ45 RS-485 OUT
connections to a multiplexer or DVMRe. This ensures proper termination.
KEYPAD IN (RS-422 and RS-485 data in from keypad; RS-422 data and power out to keypad)
AUDIO IN (from keypad)
PIN 1 to RS-485 shield (ground one end only)
PIN 3 to RS-485 A
PIN 6 to RS-485 B (PINs 2, 4, 5, 7, and 8 are not connected.)
78910653214
POWER
12 VDC
BIAS
SWITCH
78910653214
RS485
A
B
A
B
+
AUDIO KEYPAD RS485 RS485
A
B
RS422 IN
RS422 OUT
SPEAKER SHIELD
SPEAKER
REMOVABLE
TERMINAL STRIP
EARTH GROUND
12345678
78910653214
78910653214
POWER
12 VDC
BIAS
SWITCH
78910653214
RS485
A
B
A
B
+
AUDIO KEYPAD RS485 RS485
A
B
RS422 IN
RS422 OUT
SPEAKER SHIELD
SPEAKER
REMOVABLE
TERMINAL STRIP
EARTH GROUND
Observe polarity for:
•audio
•RS-422
•RS-485
• 12 VDC power. Transformer must have a
positive center-polarity plug
Note: When using multiple keypads, you can
connect CyberDomes and other receivers to
the RS-422 output from any keypad.Only one
RS communication can be chained together,
if both are hooked up on 405 I/O boxes then
performance will degrade or it will not work
at all.
A
B
C
D
E
F
G
H
I
J
K