DE7300-EE DE7300-ME DE7300-SE DE7300-MM DE7300-MS DE7300-SS DE7300-M3 DE7300-S3 DE7400-M DE7400-S DE7400-MM DE7400-SS DE7400-MS IFS Fiber Module Installation & Operation Instructions P/N 1062841 • REV B • ISS 01OCT11
DE7300 SERIES LOSS OF SIGNAL Fiber Port A LOSS OF SIGNAL Fiber Port B LOSS OF SIGNAL Fiber Port C FIBER LINK CONTACTS (All Optical Ports) On LOS A Off CONTACT CLOSURE FOR LOS On On NO CONTACT CLOSURE LOS B Off CONTACT CLOSURE FOR LOS LOS B NO CONTACT CLOSURE LOS C Off CONTACT CLOSURE FOR LOS LOS A LOS C NO CONTACT CLOSURE 3 Normal Open 2 COM 1 Normal Closed
DE7300 SERIES D A C B H E F A B C D E F G H I I G Fiber port A Fiber port B Link Speed (Channels A & B) Simplex/Duplex (Channels A&B) Power connection Power LOS A, B, C switch Fiber link contacts connection Port connection GREEN = 100 RED = 10 GREEN = DUPLEX OFF = SIMPLEX LED illuminates with fiber connection
DE7400-S GIGABIT ETHERNET MEDIA CONVERTER LNK 10/100/1000TX ACT TX 10/100/1000TX NO - 3 1000FX CONTACT CLOSURE RX COM - 2 NC - 1 ifs -3 LOS - 2 -1 Inter nati onal F i ber Sy s tem s Inc or por ated OFF POWER POWER -2 +12-24 VDC - 1 Multimode fiber optic cable DE7300-SS 3 PORT GIGABIT ETHERNET SWITCH TX PORT C 10/100/1000TX B 1000FX 10/100/1000TX RX NO - 3 CONTACT CLOSURE COM - 2 NC - 1 LNK TX ACT ifs A 1000FX RX -3 LOS B - 2 LOS A - 1 Inter nati onal F i ber Sy s tem s I
IF YOUR POWER OUTLET DOES NOT HAVE A CONNECTION TO GROUND: For proper installation the DE7100-XX stand alone units must be attached to earth ground. Ordinarily, this is accomplished through the power supply. If your power outlet does not have a ground prong then a wire must be attached from the power connector to ground. Connect the green wire included, from ground to the power connector as shown below.
FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. Changes or modifications not expressly approved by International Fiber Systems, Inc. could void the user’s authority to operate the equipment.
Contacting us For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time). Table 3. Sales and support contact information Sales Phone: Toll-free: 888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada. Outside the toll-free area: 503.885.5700.
Product Disassembly Instructions for WEEE Per European Directive 2002/95/EC Waste Electrical and Electronic Equipment Required Tools: One number 2 Phillips (crosstip) screwdriver. One number 2 flat screwdriver. For the enclosed box version: 1. Locate and remove box cover securement screws. Usually, but not limited to, at least 4 screws. 2. Lift off box top cover. 3. Locate and remove securement screws for printed circuit board. 4.
Copyright Trademarks and patents Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives © 2011 UTC Fire & Security. All rights reserved. Interlogix and IFS names and logos are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. UTC Fire & Security Americas Corporation, Inc.