D7420 D7420WDM D7420-R3 D7430WDM D7430WDM-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062847 • REV B • ISS 01OCT11
D7400 SERIES 10 / 100 AUTO-MDI (PORTS 1 - 4) Transmit + (Pin 1) Transmit - (Pin 2) Receive + (Pin 3) Receive - (Pin 6) NOTE: Pins 4, 5, 7, 8 are not used. 10 / 100 MDI-X (PORTS 1 - 4) Receive + (Pin 1) Receive - (Pin 2) Transmit + (Pin 3) Transmit - (Pin 6) NOTE: Pins 4, 5, 7, 8 are not used.
To\From next port "A" Single mode fiber optic cable D7430WDM DROP AND REPEAT 4 - PORT ETHERNET SWITCH ifs Inter nati onal F i ber Sy s tem s Inc or por ated C2B - 4 FIBER LINK CONTACTS POWER C2A - 3 C1B - 2 C1A - 1 -2 + 12 VDC - 1 Single mode fiber optic cable D7430WDM DROP AND REPEAT 4 - PORT ETHERNET SWITCH ifs Inter nati onal F i ber Sy s tem s Inc or por ated C2B - 4 FIBER LINK CONTACTS POWER C2A - 3 C1B - 2 C1A - 1 -2 + 12 VDC - 1 Single mode fiber optic cable D7430WDM DROP AND REPEAT 4
D7400 SERIES FIBER PORT LINK / SPEED 10 / 100 PORT 1 A 2 3 4 DUPLEX 10 / 100 PORT B 1 2 3 B C D POWER 4 E NOTE: WITHOUT PROPER FIBER CONNECTION, LED's DO NOT INDICATE CORRECT OPERATIONAL STATUS OF THE UNIT.
INSTALLATION INSTRUCTIONS FOR ADDITIONAL COMPONENTS REQUIRED TO MEET EMISSION REQUIREMENTS ON THE D74XX/D74XXWDM STAND ALONE UNITS AND D74XX-R3/D74XXWDM-R3 RACK UNITS. POWER CABLE MUST HAVE A FERRITE TOROID CORE IFS P/N LB2643801002, FAIR-RITE P/N 2643801002 INSTALLED NEAR THE CONNECTOR WITH CABLE PASSING THRU IT FIVE TIMES (FIVE TURNS). REQUIRED FOR STAND ALONE UNITS ONLY.
IF YOUR POWER OUTLET DOES NOT HAVE A CONNECTION TO GROUND: For proper installation the D74XX, D74XXWDM stand alone units must be attached to earth ground. Ordinarily, this is accomplished through the power supply. If your power outlet does not have a ground prong then a wire must be attached from the power connector to ground. Connect the green wire included, from ground to the power connector as shown below.
FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. Changes or modifications not expressly approved by International Fiber Systems, Inc. could void the user’s authority to operate the equipment.
Contacting us For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time). Table 3. Sales and support contact information Sales Phone: Toll-free: 888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada. Outside the toll-free area: 503.885.5700.
Product Disassembly Instructions for WEEE Per European Directive 2002/95/EC Waste Electrical and Electronic Equipment Required Tools: One number 2 Phillips (crosstip) screwdriver. One number 2 flat screwdriver. For the enclosed box version: 1. Locate and remove box cover securement screws. Usually, but not limited to, at least 4 screws. 2. Lift off box top cover. 3. Locate and remove securement screws for printed circuit board. 4.
Copyright Trademarks and patents Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives © 2011 UTC Fire & Security. All rights reserved. Interlogix and IFS names and logos are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. UTC Fire & Security Americas Corporation, Inc.