D1210 D1210-R3 D1220 D1220-R3 D1225 D1225-R3 D1230 D1230-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062853 • REV B • ISS 01AUG11
D1200 T1 INPUT T1 OUTPUT 6 5 4 3 2 1 6 5 4 3 2 1 Ground - Data In + Data In Ground - Data Out + Data Out
D1210 T1 TRANSCEIVER OPTICAL IN GRD - 6 T1 OUTPUT ifs International + DATA OUT - 4 GRD - 3 Fiber Systems - DATA OUT - 5 T1 INPUT Incorporated - DATA IN - 2 + DATA IN - 1 } } T1 Data Output T1 Data Input OPTICAL OUT CARRIER DETECT 24 VAC CENTER TAPPED POWER AC - 3 GRD/CT - 2 AC - 1 Blue Green Brown Duplex multimode fiber optic cable D1210 T1 TRANSCEIVER OPTICAL IN GRD - 6 T1 OUTPUT ifs International + DATA OUT - 4 GRD - 3 Fiber Systems - DATA OUT - 5 T1 INPUT Incorporated - DATA IN
D1200 A B E D C 1 2 3 A Carrier Detect B Power C Power Connector D Optical Out E T1 Connector F Optical In 1 2 3 4 5 6 LED illuminates LED illuminates NOTE: WITHOUT PROPER FIBER CONNECTION, LED's DO NOT INDICATE CORRECT OPERATIONAL STATUS OF THE UNIT.
FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. Changes or modifications not expressly approved by International Fiber Systems, Inc. could void the user’s authority to operate the equipment.
Contacting us For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time). Sales and support contact information North America Toll-free: 855.286.8889 in the US, including Alaska and Hawaii; Puerto Rico; Canada. Outside the toll-free area: 503.885.5700.
Product Disassembly Instructions for WEEE Per European Directive 2002/95/EC Waste Electrical and Electronic Equipment Required Tools: One number 2 Phillips (crosstip) screwdriver. One number 2 flat screwdriver. For the enclosed box version: 1. Locate and remove box cover securement screws. Usually, but not limited to, at least 4 screws. 2. Lift off box top cover. 3. Locate and remove securement screws for printed circuit board. 4.
Copyright Trademarks and patents Manufacturer Certification ACMA compliance Canada European Union directives © 2011 UTC Fire & Security. All rights reserved. Interlogix and IFS names and logos are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. UTC Fire & Security Americas Corporation, Inc.