Installation Instructions

Proximity Reader P60-W01
Page
4
How to Correctly Present the Identification Medium
In order to permit a correct data capture, the identification medium must be presented within
the specified range and in parallel to the proximity reader until the red or green LED lights up
and a short “beep” can be heard (see figure).
A
1
2
A Card presentation
1 Card 2 LED:display
LEDs
The LEDs signalize:
- Blue LED light => operational readiness of the reader
- Green LED light => a door opening
- Green LED light and a short “Beep” => positive booking response followed by a door
opening
- Red LED light and “Beeps” repeated at intervals => a negative booking response
Access Manager - Configuration
Access managers are only able to read the transmitted data if the reader is defined as of HID/P type.
The reader type setting can be checked via the OC menu
1
$ cfg (see also “read1” of the table
below). Define the reader type via the OC menu $ termini –x (x = hardware address of the
terminal) if another reader type than HID/P is indicated.
$ cfg
No B A HA TNo type HWU SWU display keys read1 read 2 In/ Out
x x x x x IF 610 2.01 x - - Prox - -
1
The OC menus are part of the IF 1xxx software and can be invoked via the service interface of these systems.