User's Manual

Intercontinental Technologies, Ltd.
Chapter 11 Page 37 of 87
Table 11.2: Alarm Codes for Receivers
Error Message Item
Alarm Code
Description Possible Correction
17 R
. - .
The voltage input exceeds
tolerance.
1. Disconnect the cable from
the receiver.
2. Turn off the main power to
the crane and check the
power-input voltage.
3.Check to see that the voltage
select plug is at the correct
position. (handhelds only)
4. Inspect and make sure the
power is normal before
resuming operation.
18 S
. . .
RF Circuit malfunction 1. Ensure antenna is tight.
2. Replace the receiver/
decoder module.
19 Y
- . - -
Interference by the same
model of Remote Controller
1.Install a less sensitive
antenna.
2.Change to a new frequency.
(Contact ITL or your dealer).
20 1
. - - - -
Interference by another radio
signal on the same frequency
1. If the interference is not
serious or is short term,
start the Remote Controller
when the interference is
over.
2. If the interference is serious,
change to a new frequency.
(Contact ITL or your
dealer).
21 Z
- - . .
EEPROM in the
receiver/decoder does not
have function settings set or
are incomplete.
Reprogram function settings
(see Chapter 9).