User's Manual
Table Of Contents
- Cover of F21F24 manual 4.pdf
- blank side cover.pdf
- F21 wiring diagrams for manual 4a.pdf
- F24 wiring digram for manual 4a.pdf
- F21-2S BUTTON PROGRAMMING2.pdf
- blank side F21-2S.pdf
- F21-2D BUTTON PROGRAMMING2.pdf
- blank side F21-2D.pdf
- F21-4S BUTTON PROGRAMMING2.pdf
- blank side F21-4S.pdf
- F21-4D BUTTON PROGRAMMING2.pdf
- blank side F21-4D.pdf
- F21-6S BUTTON PROGRAMMING2.pdf
- blank side F21-6S.pdf
- F24-6S BUTTON PROGRAMMING2.pdf
- blank side F24-6S.pdf
- F24-6D BUTTON PROGRAMMING2.pdf
- blank side F24-6D.pdf
- F24-8S BUTTON PROGRAMMING2.pdf
- blank side F24-8S.pdf
- F24-8D BUTTON PROGRAMMING2.pdf
- blank side F24-8D.pdf
- F24-10S BUTTON PROGRAMMING2.pdf
- blank side F24-10S.pdf
- F24-10D BUTTON PROGRAMMING2.pdf
- blank side F24-10D.pdf
- F24-12S BUTTON PROGRAMMING.pdf
- blank side F24-10S.pdf
- F24-12D BUTTON PROGRAMMING.pdf
- blank side F24-10D.pdf
- blank side cover.pdf
- back page address back side of F24-10D.pdf

normal, not interlocked
toggle (on/off)
off (on is button “UP”)
normal, interlocked with button “UP”
normal, not interlocked
toggle (on/off)
off (on is button “EAST”)
normal, interlocked with button “EAST”
normal, not interlocked
toggle (on/off)
off (on is button “SOUTH”)
normal, interlocked with button “SOUTH”
normal, not interlocked
toggle (on/off)
off (on is button “1”)
normal, interlocked with button “1”
normal, not interlocked
toggle (on/off)
on (off is button “DOWN”)
normal, interlocked with button “DOWN”
normal, not interlocked
toggle (on/off)
on (off is button “WEST”)
normal, interlocked with button “WEST”
normal, not interlocked
toggle (on/off)
on (off is button “NORTH”)
normal, interlocked with button “NORTH”
normal, not interlocked
toggle (on/off)
on (off is button 2)
normal, interlocked with button “2”
normal, not interlocked
toggle (on/off)
on (off is button “4”)
normal, interlocked with button “4”
normal, not interlocked
toggle (on/off)
off (on is button “3”)
normal interlocked with button “3”
normal
toggle (on/off)
inching .4 seconds
inching .5 seconds
inching .6 seconds
inching .1 seconds
inching .7 seconds
inching .2 seconds
inching .8 seconds
inching .3 seconds
acceleration .4 seconds
acceleration .5 seconds
acceleration .6 seconds
acceleration .1 seconds
acceleration .7 seconds
acceleration .2 seconds
acceleration .8 seconds
acceleration .3 seconds
Acceleration delay for all button relays.
Default setting of ZERO
10 minutes
20 minutes
30 minutes
1 hour
2 hours
3 hours
4 hours
Auto Shut Down time
Default setting of 1 hour
never
1.5 seconds
2 seconds
3 seconds
.3 seconds
4 seconds
.5 seconds
1 second
F24-10D
NOTES: For each button there is a default function setting labeled in bold, if you wish to change any button function check the appropriate circle for that button.
If you want to re-label any button, fill in the squares in the appropriate section. Use only the squares available.
Intercontinental Technologies Ltd. 558 Plate Drive Bldg. #2, East Dundee, IL 60118