Sensor sealing
The sealing is an extreme important procedure. From this it depends the sensor’s functionality.
The product to use to seal the sensor
must be DOWSIL™ 7091 Adhesive Sealant
(hiips://www.dow.com/en -us/pdp.dowsil-7091-adhesive-sealant.02436621h.html), or with the
exactly the same specifications, with these recommended procedure:
Do this procedure in a clean and dry ambient, with humidity <60%
Clean very well the contact surfaces
Put the sealeant in the correct position
Close the box and insert and tighten the screws
Wait 48 hours before to install sensors
At the following link is possible to see a video demonstration of the Sealing Procedure.
hiips://smartparkingsystems.com/tech -video/
!!! ATTENTION !!!
The use of a sealant product with different specification (eg a simple silicon sealant), it could have
detrimental effects on sensors even in the short term. The expansions of materials due to
temperature variations, and the use of a non-compliant product can favor the penetration of
humidity inside the sensor box.