4.7.
Sensor setup
4.7.1.
"Ready to install" state
All
Ecoh 915
sensors delivered are configured with the parameters and keys communicated by
customer. Usually the ID assigned to each sensor are the same of the parking bay where it will be
installed.
If any configuration was requested, sensors will be delivered with a standard parameters and user
must
complete the configuration before to install them.
It’s suggested to prepare the sensors for final installation in a lab to speed up the installation
processes in the field.
The
Ecoh 915
sensor has a power-on process in order to put the device into a "ready for use " state.
Sensor Configuration App for Windows and the USB programming cable are needed to proceed.
Step 1: Connect the USB cable to the PC and connect the 2 connectors, one for power and one
for TX-RX to sensor;
Step 2: Run Sensor Configuration App and select the correct COM port (verify it in Windows
Device Manager);
Step 3: When sensor will enter in programming mode a red LED on PCB will become fixed.
Step 4: Within 10 seconds click on Connect button on Sensor Configuration App.