Brochure

1. FAN
Airflow intake multi-stage quiet fans ensures amplifier cooling.
2. PROT (protection circuit indicators)
LED indicator displays if the amplifier protection mode.
3. POWER LED
LED indicates power ON / OFF status five times as this unit is
lit if the power switch ON and work instructions.
4. OUTPUT LEVEL INDICATOR
LED indicates output power level.
5. POWER SWITCH
An LED indicator confirms power on status of the amplifier.
1. OUTPUT TERMINAL
Allows selection of low impedance, 70.7 or 100 volt high
impedance output.
2. LEVEL ADJUST VOLUME
Rear mounted trim pot offers -12dB volume adjustment the
nominal output. (Variable output voltage of up to 75%).
3. VENTILATION
Ventilation out-take.
4. AC POWER INPUT
117VAC/60HZ 220 VAC50HZ
5. FUSE
6. HPF Switch
400Hz, High Pass Filter On/off switch
7. Signal input terminal
Phoenix-style terminals
8. Ground Lift Switch
This switch provides for connection or disconnection of the
amplifier’s ground to AC “earth” ground, to prevent noise from
ground loops. Under most circumstances, this switch should be
set to FRAME position.
9. 24V DC back up power
These terminals are provided for the connection of backup
battery. Connect a 24VDC(100A) battery source to these
terminals. Make certain the red terminal is connected to the
battery’s positive (+) side, and the black terminal to the battery’s
negative (-) side.
www.inter-m.com
1 2 3
4 5
1 3
2
4 5 6 7 8 9
Front / Rear Panel