MADE IN KOREA August 29, 2012
Operation Manual Audio Matrix Controller PX-6216 TYPE A European Area TYPE B America
Features - 16 X 8 AUDIO MATRIXES Digital audio matrix, 16 inputs x 8 outputs. Computer controlled, this unit is the main component of the 6000 system 8 bus. (EM, Timer, RM x4, BGM x10). - PC CONTROL System Control and configuration is possible via our windows based system software. Remote operation and connectivity is made possible using the DIB-6000.
Front Panel TYPE A European Area TYPE B America 1. PRESET MEMORY BUTTON AND INDICATOR 6 front panel preset buttons can be programmed and operated even when the control PC is offline. LED indicators identify the active present. 2. POWER INDICATOR This LED will be on when Power the PX-6216 is on. It will blink if communication error with the PC occurs.
Rear Panel 1. BGM INPUT TERMINAL TYPE A European Area - INPUT 1 and 2 : Connection of BGM sources is possible via the 2 XLR combo jack channels. Condenser microphones with 24V PHANTOM POWER can be connected on channel 1 and 2. These inputs can select between MIC/Line inputs through setting of operation programs. - INPUT 3~8 : 6 XLR channels, - INPUT 9~10 : 2 RCA stereo input jacks.
5. AUDIO OUTPUT TERMINAL 8 bus balanced audio output terminal. 6. EMERGENCY PANEL (EP) CONNECTION TERMINAL This terminal allows for connecting emergency panel unit (EP-9216,9216V,616,6216, etc.) with priority broadcasting. 7. RS-232 SOURCE UNIT CONTROL TERMINAL RS-232 communication terminal allows control inter-M source units (CDP, TUNER, VOICE FILE, etc.) via the PC operation program.
8. DATA LINK IN/OUT TERMINAL Communication terminal for Windows PC system control. LINK IN terminal is connected with DIB-6000 and LINK OUT terminal is connected with following equipment. 9. POWER INPUT TERMINAL DC Power input terminal. Caution please observe polarity when connecting DC 24V. Connect to an external power supply or inter-M power distributor. Connect to un-switched power supply.
Equipment Setting and Caution 1. EP CONNECTION 1) When connecting with EP equipment, please connect the matrix terminal of EP and emergency panel connection terminal by using the EP connector supplied as an accessory of the PX-6216. 2) Connect the audio signal of PRE OUT of EP to EP audio input terminal on the top of PX-6216. Volume control of EP input can be set in the equipment setting of operation program. 2.
Block Diagram TYPE A European Area
Block Diagram TYPE B America
Specifications PX-6216 Rated Output 0dBV (Balanced) EM, TIMER, RM -10dBV/20kΩ (Balanced) BGM 1~8 LINE -10dBV/3kΩ (Balanced) BGM 1~8 MIC -50dBV/3kΩ (Balanced) BGM 9,10 LINE -10dBV/20kΩ (Unbalanced) ±3dB 20Hz~20kHz LINE Less than 0.01% MIC Less than 0.
※ DIMENSIONS TYPE A European Area
※ DIMENSIONS TYPE B America
Service Procedures Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual. Schematic A Schematic is available by contacting your warranty provider. Parts List A Parts List is available by contacting your warranty provider.