Protocol Document

INTER-M Remote Control Protocol – CD Player(061012) 1/6
INTER-M CD Player Remote Control Protocol
Model : CD-610
1. Outline
This document is remote control protocol description for using Inter-M CD player CD-610 with RS-232
port. Protocol is consist of two protocol, control signal and condition reply protocol. If control signal
protocol which is defined in this document is transferred to RS-232 port of CD-610, CD-610 is
functioned by control signal. When the status of operation is changed, CD-610 send the status reply
protocol to external controller. External control system receives this signal with showing its status on
display and confirm whether it is work properly or not. Status Reply signal protocol can be sent when any
buttons are pressed on CD player, remote controller is working, controlling with RS-232 protocol.
1 Communication Standard
Communication
Type
UART(RS-232C) communication
Baudrate
9600 bps
Data Bit
8 bit
Stop Bit
1 bit
Parity
No Parity

Summary of content (6 pages)