Instructions
37
Gigabit Ethernet PoE+ Web-Managed AV Switch User Manual
o The alarm value is read-only and shows the sampled value when the alarm
was last issued. The rising threshold shows a number at which the alarm
is triggered. This value ranges between 0 and 2147483647.
o The falling threshold, a number at which the alarm is reset.
This value ranges between 0 and 2147483647.
• Value, event index and owner are optional.
• The event index refers to the index number of the RMON event
group and must be congured in advance.
RMON EVENT GROUP CONFIGURATION
The following image shows the RMON event group configuration page.
Select a configured event group from the drop-down list to view/configure its information. Select New to
create one.
• The index number range is from 1 to 60.
• The description is a character string.
• Type can be one of:
o none (no operation)
o log (log)
o snmp-trap (trap trap)
o log-and-trap (log and trap alarm)
o Community names are not required.
o Owner is optional.
o The Last Time Sent is read-only, showing the last time the event was sent.
Switch