Instructions

36
Gigabit Ethernet PoE+ Web-Managed AV SwitchUser Manual
RMON STATISTICS GROUP CONFIGURATION
The following image shows the RMON statistics group configuration page.
Select a port from the drop-down list to view/configure the RMON statistics group configuration for this port.
When not configured, the index number is 0. Fill in the index number (range 1 to 100); the owner is optional.
The statistics table shows the port statistics after successful configuration.
RMON HISTORY GROUP CONFIGURATION
The following image shows the RMON history group configuration page.
Select a port from the drop-down list to view/configure the RMON history group configuration for this port.
When not configured, the index number is 0. Fill in the index number (range is 1 to 100), interval, request
buckets; the owner is optional.
Interval refers to the time interval in seconds that the data is collected. The range is 1-3600. The bucket is the
allocated storage size, and it indicates how many records are stored. The range is 1-100. The statistics table
shows historical data that has been collected since the configuration was successful.
RMON ALARM GROUP CONFIGURATION
The image on the next page shows the RMON alarm group configuration page. From this page, you can:
Select a congured alarm group from the drop-down list to view/congure its information.
Select New to create an alarm group: the index number range is from 1 to 60, and the
interval range is from 1 to 3600 (In seconds). In the variable eld specify the MIB that is
monitored by the alarm entry. The comparison method can be absolute or delta.
Switch