5.4.4  ATM Loopback 
In order to isolate ATM interface problems, you can use ATM OAM loopback 
cells to verify connectivity between VP/VC endpoints, as well as segment 
endpoints within the VP/VC. This screen allows you to use ATM ping to test the 
reachability of a segment endpoint or a connection endpoint. 
Parameter 
Description 
Select PVC 
Select the PVC channel you want to do the loop-back 
diagnostic. 
Flow Type 
The ATM OAM flow type. The selection can be F5 Segment or 
F5 End-to-End. ATM uses F4 and F5 cell flows: 
• F4: used in VPs 
• F5: used in VCs 
Loopback 
 Location ID 
The loop-back location ID field of the loop-back cell. The 
default value is all 1s (ones) to indicate the endpoint of the 
segment or connection. 
Click “Go!” to save the setting to the configuration. 