User Manual

FRONT PANEL
Inputs & Outputs
[1] CH 1 input: The input is DC
coupled and accepts signals
between -10V and +10V.
[2] CH 2 input: This input, like CH 1,
is DC coupled and accepts signals
between -10V and +10V.
[3] CH 1 output: The signal
appearing at the CH 1 input jack is
normalled to the CH 1 output jack,
so signals pass unimpeded
through the Zeroscope 1U. This allows you to monitor signals without needing to re-patch or use
signal multipliers.
[4] CH 2 output: As with CH 1, the signal appearing at the CH 2 input jack is normalled to the CH 2
output jack, so signals pass unimpeded through the Zeroscope 1U.
Controls
[A] Scope : In Scope or X-Y modes, this screen displays both the CH 1 and CH 2 waveforms, while
in Tune mode, it displays their frequency by either Hz or note name.
[B] Encoder : This push-function encoder serves multiple functions controlling the appearance of
the scope, and enabling both the selection of parameters and the editing of their values.
Zeroscope 1U Manual 6