User Manual

You can use a tool like ModularGrid to assist in your planning. Failure to adequately power your
modules may result in damage to your modules or power supply. If you are unsure, please contact
us before proceeding.
Installing Your Module
When installing or removing a module from your case
always turn off the power to the case and disconnect the
power cable. Failure to do so may result in serious injury
or equipment damage.
Ensure the 10-pin connector on the power cable is
connected correctly to the module before proceeding. The
red stripe on the cable must line up with the -12V pins on
the module’s power connector. The pins are indicated
with the label -12V, a white stripe next to the connector,
the words “red stripe”, or some combination of those
indicators.
Most modules will come with the cable already connected but it is good to double check the
orientation. Be aware that some modules may have headers that serve other purposes so ensure
the cable is connected to the right one.
The other end of the cable, with a 16-pin connector,
connects to the power bus board of your Eurorack
case. Ensure the red stripe on the cable lines up with
the -12V pins on the bus board. On Intellijel power
supplies the pins are labelled with the label “-12V”
and a thick white stripe:
If you are using another manufacturer’s power supply,
check their documentation for instructions.